Mitutoyo-SERIES 293 — IP65 Micrometer with 2mm/rev Spindle Feed-QuantuMike

293-140

293-140

 

 

 SPECIFICATIONS

Metric

  Order No. Range Resolution Accuracy*1 Flatness Parallelism Mass

 

with SPC data output

293-140-30 0 – 25mm

 

 

 

0.001mm

 

±1µm

 

 

 

0.3µm

1µm 265g
293-141-30 25 – 50mm 325g
293-142-30 50 – 75mm

 

2µm

465g
293-143-30 75 – 100mm ±2µm 620g

 

without  SPC

data output

293-145-30 0 – 25mm

 

±1µm

 

1µm

265g
293-146-30 25 – 50mm 325g
293-147-30 50 – 75mm 2µm 465g
293-148-30 75 – 100mm ±2µm 620g

*1  Excluding quantizing error

Inch/Metric

  Order No. Range Resolution Accuracy*1 Flatness Parallelism Mass

 

with SPC data output

293-180-30 0  – 1″

 

 

 

.00005″/

0.001mm

 

±.00005″

 

 

 

.000012″

.00004″ 265g
293-181-30 1″ – 2″ 325g
293-182-30 2″ – 3″

 

.00008″

465g
293-183-30 3″ – 4″ ±.0001″ 620g

 

without  SPC

data output

293-185-30 0  – 1″

 

±.00005″

 

.00004″

265g
293-186-30 1″ – 2″ 325g
293-187-30 2″ – 3″ .00008″ 465g
293-188-30 3″ – 4″ ±.0001″ 620g

*1  Excluding quantizing error

DIMENSIONS

IP Codes

Level 6: Dust -proof.
No ingress of dust allowed.
Level 5: Protected against water jets.
Water projected in jets against the enclosure from any direction shall have no harmful effects.
Technical Data

Dust/Water protection level: IP65 (IEC60529)*2
Measuring force:  7 to 12N*3
Battery:  SR44 (1 pc), 938882,   for initial operational checks (standard accessory)
Length standard:  Electromagnetic rotary sensor
Battery life:  Approx. 1.2 years under normal use
Standard accessories: Reference bar, 1 pc   (except for 0-25mm (0-1”) models)  Spanner (No. 301336), 1 pc
*2 Rustproofing shall be applied after use.
*3 Measuring force when using the speeder ratchet
(Apply a measuring force in the same condition as for measurement and then set the origin.)
Functions

Origin point setting (ABS length measurement system):

Pressing the ORIGIN button resets the ABS origin at the current spindle position. Origin values can be set depending on each size.

Zero setting (INC length measurement system):

A brief press on the ZERO/ABS button sets display to zero at the current spindle position and switches to the incremental (INC) measuring mode. A longer press resets to the ABS measuring mode.

Hold:

Pressing the HOLD button freezes the current value in the display. This function is useful for preserving a measurement in situations of poor visibility when the instrument must be moved away from the workpiece before the reading can be recorded.

Function lock:

This function allows the ORIGIN (origin point setting) function and the ZERO (zero setting) function to be locked to prevent these points being reset accidentally.

Auto power ON/OFF:

The reading on the LCD disappears after this instrument is idle for approx. 20 minutes, but the origin point is retained. Turning the spindle causes the reading on the LCD to reappear.

Data output*4:

Models equipped with this function have an output port for transferring measurement data to a Statistical Process Control (SPC) system.

Error alarm:

In case of an overflow on the LCD or a computing error, an error message appears on the LCD, and the measuring function stops. This prevents an instrument from giving an erroneous reading. Also, when the battery voltage drops to a certain level, the low-battery-voltage alarm annunciator appears well before the micrometer becomes unusable. *4: Only for the models with SPC data output.

Optional accessories

(Only for models with data output function)

Connecting cables with output switch

1m: No. 05CZA662

2m: No. 05CZA663USB

Input Tool Direct

USB-ITN-B (2m): No. 06ADV380B

Connecting cables for U-WAVE-T (160mm)

No. 02AZD790B

For foot switch: No. 02AZE140B  Refer to page A-21 for details.