Description: Push and pull test Units: N, gf, kgf, ozf, lbf 500 memories Automatic power off Metal case LCD display with backlight The display flips over when the bottom faces up Overload alarm Specification: Code ISF-1DF10 ISF-1DF50 ISF-1DF100 ISF-1DF500 ISF-1DF1000 Load capacity (N) 10 50 100 500 1000 Resolution (N) 0.01 0.01 0.1 0.1 […]
Description: Push and pull test Peak (max.) and tracking mode Units: mN, N, gf, kgf, ozf, lbf, MPa (only for type B) Tolerance testing 1000 memories Automatic power off Metal case, touch buttons LCD display with backlight The display flips over when the bottom faces up Overload alarm Specification: Code ISF-DF 5A ISF-DF 10A ISF-DF […]
Description: Can change probes Dual-coil probe for high accuracy Universal testing angle, no need to set impact direction Based on Leeb (HLD), converted to Vickers (HV), Brinell (HB), Rockwell (HRC, HRA and HRB), Shore (HS) and tensile strength (SGM) Dual value display, shows both Leeb and converted hardness Large LCD display with backlight Can choose […]
Description: Metal housing HD TFT 320×320 display Impact device D Accuracy: ±4HLD(when HLD=800) Based on Leeb (HLD), converted to Vickers (HV), Brinell (HB), Rockwell (HRC, HRA and HRB), Shore (HS) and tensile strength (SGM) Four display modes Automatic direction correction Low and high limits with judgement Automatic power off, automatic calculation of statistics Dual value […]
Description: Impact device D Universal testing angle, no need to set impact direction Dual-coil probe, high accuracy Based on Leeb (HLD), converted to Vickers (HV), Brinell (HB), Rockwell (HRC, HRA and HRB), Shore (HS) and tensile strength (SGM) Dual value display, shows both Leeb and converted hardness High contrast digital LCD display Can choose large […]
Specification: Hardness scale HRA, HRB, HRC, HRD, HRF, HRG Preliminary test force 98N (10kg) Test force 588N (60kg), 980N (100kg), 1471N (150kg) Display analogue Stage elevation manual Load control manual Min. reading 0.5HR Max. workpiece height 170mm Max. workpiece depth 135mm (from the center of indenter) Dimension 466x238x630mm Weight 70kg Standard Delivery: Main unit 1 […]
Description: Accumulate and record the number of mechanical movements Rotate back to zero Specification: Code Number of digits Range 7600-6 6 0-999999
Description: Quickly measure the concentration of coolant Refer to the refraction factor of coolant, for example: the refraction factor of grinding emulsion is 2.1, the reading value is 6%, so the actual concentration is (2.1×6%)=12.6% Specification: Measuring range 0-32% Graduation 0.2% Dimension 27x40x160mm Weight 175g
Description: Quickly measure the concentration of coolant Two measurement modes: single measurement and automatic average multiple measurement Two units: brix and refractive index Refer to the refraction factor of coolant, for example: the refraction factor of grinding emulsion is 2.1, the reading value is 6%, so the actual concentration is (2.1×6%)=12.6% Automatic power off Specification: […]
Description: Auto/manual ranging Maximum mode Data hold Display backlight Work light Low battery display Auto power off Safety rating: CAT Ill 600V Specification: Function Range Resolution Accuracy DC Voltage 200mV/2V/20V/200V 0.1mV/1mV/10mV/0.1V ±(0.8%+2) 600V 1V ±(1.0%+2) AC Voltage 2V/20V/200V 1mV/10mV/0.1V ±(1.0%+5) 600V 1V ±(1.2°/0+5) AC Current 2A(50.5A) 1mA ±(3.5%+20) 2A 1mA ±(3.0%+10) 20A 10mA ±(3.0%+10) 200A […]
Description: Data hold Display backlight Low battery display Safety rating: CAT II 600V Specification: Function Range Resolution Accuracy DC Voltage 200mV/2V/20V/200V 0.1mV/1mV/10mV/0.1V ±(0.5%+3) 600V 1V ±(0.8%+5) AC Voltage 200V/600V 0.1V/1V ±(1.2%.+10) DC Current 200pA/2mA 0.1pA/1pA ±(1.0°/0+3) 20mA 10pA ±(1.0°/0+5) 200mA 0.1mA ±(1.5%+5) 10A 10mA ±(3.0`)/0+10) Resistance 2000 0.10 ±(0.8%+5) 2k0/20k0/200k0 10/100/0.1k0 ±(0.8%+2) 2M0 1 k0 […]
Description: Measure visible light emitted by fluorescent lamp, metal halide lamp, high voltage sodium lamp or incandescent lamp Min/Max, data hold Two units: LUX and FC Reading in digital and analog Display backlight Auto power off Specification: Measuring range 0-200000LUX (0-20000FC) Resolution 0.1LUX (range<1000LUX), 1LUX (range?-1000LUX) 0.01FC (range<100FC), 0.1FC (range<1000FC), 1FC (range?-1000FC) Accuracy ±4% RED […]
Description: Measure humidity, ambient temperature, dew-point temperature and wet dulb temperature Min/Max/Average, data hold function Display backlight Auto power off Specification: Function Measurin ran e Resolution Accuracy Ambient temperature -20°C-60°C/-4°F–140°F 0.1°C/0.1°F ±1°012°F Wet dulb temperature -20°C-60°C/-4°F-140°F Dew-point temperature -10°C-50°C/14°F-122°F Humidity 0-99.9%RH 0.1 (YoRH ±5%RH Date storage 99 groups Auto power off 30 minutes Weight 190g […]
Description: Maximum and minimum modes Memory 100 measurement values Automatic power off Specification: Standard Delivery: Main unit 1 pc Reflection sticker 1 roll Battery (AAA) 4 pcs
Description: Unit: RPM, m/min, m/sec, ft/min, ft/sec, in/min Maximum and minimum modes Memory 100 measurement values Automatic power off Specification: Measuring range 50-19999RPM Accuracy ±(0.03%+2) RPM Resolution 0.01RPM (range 50-99.99RPM) 0.1 RPM (range 100-9999.9RPM) 1RPM (range 10000-19999RPM) Power supply 4 xAAA batteries Dimension 183x60x27mm Weight 122g Standard Delivery: Main unit 1 pc Wheel with 0.1m […]
Description: Measure velocity, flow, temperature and relative humidity Velocity unit m/s, km/h,mil/h, ft/m, ft/s, knots Flow unit CMS (cubic meter per second), CMM (cubic meter per minute), CFM (cubic feet per minute) Temperature type: ambient, dew point, wet bulb Maximum and minimum modes Automatic power off Specification: Standard Delivery Main unit 1 pc USB cable […]
Description: Automatically select best range: 30-80dB, 40-90dB, 50-100dB, 60-110dB, 70-120dB, 80-130dB Over range indicator Real time, average, maximum modes Memory 16000 measurement values AC signal output: 0.707 Vrms at FS, impedance approx. 6000 DC signal output: 10mV/dB, impedance approx.1000 Automatic power off Standard Delivery Main unit 1 pc RS232 Cable and software 1 pc Output […]
Description: Suitable for wood, smooth cement, hard gypsum, mixed mortar, brick, etc. Measure moisture, temperature and relative humidity Temperature type: ambient, dew point, wet bulb Maximum and minimum modes Automatic power off Main unit 1 pc Battery(AAA) 2 pcs Specification
Description: Measure the thickness from one side of object, suitable for pipe, tank, etc. Applicable material: metal, plastic, glass, nylon, resin, ceramic, ice Standard Delivery Main unit 1 pc Transducer 1 pc Couplant 1 bottle Battery(AAA) 2 pcs Specification
Description: Magnetic induction probe (FE) measures the thickness of non-magnetic coating on magnetic substrate Substrate: iron, steel, magnetic stainless steel (not for non-magnetic stainless steel) Coating: zinc, copper, chrome, tin, plastic, powder, paint (not for nickel) Eddy current probe (NFE) measures the thickness of non-conductive coating on non-magnetic substrate Substrate: copper, aluminum, zinc, non-magnetic stainless […]
Description: IP54 dust/waterproof Resolution: 0.01 mm/0.0005″ Buttons: on/off, zero, mm/inch, ABS/REL Automatic power off after 10 minutes of no operation, move the digital unit or press the on/off button to power on Automatic power off after 72 hours of no operation, move digital unit cannot power on, press the on/off button to power on Battery […]
Description: IP67 dust/waterproof Resolution: 0.01mm/0.0005″ Large display Button function: zero, on/off, mmAnch Battery CR2032, automatic power off Meet DIN862 Made of stainless steel Code Range Accuracy Thumb roller Type L a b d 1126-150 • 0-150mm/0-6″ ±0.03mm with A 234 20 15 40 1126-200 • 0-200mm/0-8″ ±0.03mm with A 286 24 19 50 1126-300 0-300mm/0-12″ […]
Description: Built-in wireless data transfer module, Zigbee signal Transfer distance is 6 meter Resolution: 0.01mm/0.0005″ Buttons: on/off, zero, mm/inch, data transmission Automatic power off, move the digital unit to turn on power Battery CR203 Made of stainless steel Optional accessory: receiver (code 7315-2, 7315-3) Code Range Accuracy L a b c d 1113-150 0-150mm/0-6″ ±0.03mm […]