One Revolution Dial Indicators

DIMENSIONS

One Revolution Dial Indicators

Note 1: Dimensions of the inch (ANSI/AGD Type) dial indicator partly differ from those of the metric (ISO/JIS Type) indicator.

Note 2: Inch (ANSI/AGD Type) dial indicators are provided with a stem of 3/8″ dia. and #4- 48UNF thread mount for the contact point.

Order No. A B C D E F G H I
2928S 48.8 65.2 57 17.7 20 16.9 19.8 52 7.6
2929S 48.8 65.2 57 17.7 20 16.9 19.8 52 7.6
2929S-62 48.8 65.2 57 17.7 20 16.9 19.8 52 7.6
2959S 48.8 65.2 57 17.7 20 16.9 19.8 52 7.6
2900S-10 48.8 66 57 17.7 20 16.9 20.6 52 7.6
2900S-72 48.8 66 57 17.7 20 16.9 20.6 52 7.6
2901S-10 48.8 66.1 57 17.7 20 16.9 20.7 52 7.6
Order No. A B C D E F G H I
2909S-62 48.8 51.9 57 17.7 19 13.6 9.8 52 7.6
2910S-10 48.8 51.2 57 17.7 19 13.6 9.1 52 7.6

SPECIFICATIONS

Metric

Order No. Graduation Range (range/rev) Accuracy Repeat- ability Dial reading Measuring force
w/ lug Flat-back Overall Retrace 1/10 Rev 1 Rev
2928S 2928SB 0.1mm 4mm (5mm) 40µm 20µm 20µm 20µm 2-0-2 1.4N or less
2929S 2929SB 0.01mm 0.8mm (1mm) 8µm 3µm 5µm 3µm 40-0-40 1.4N or less
2929S-62 2929SB-62 0.01mm 0.8mm (1mm) 8µm 3µm 5µm 3µm 40-0-40 2.0N or less
2959S 2959SB 0.01mm 1.6mm (2mm) 10µm 3µm 5µm 3µm 80-0-80 1.4N or less
2900S-10 2900SB-10 0.001mm 0.08mm (0.1mm) 3µm 2µm 2µm 0.5µm 40-0-40 1.5N or less
2900S-72 2900SB-72 0.001mm 0.08mm (0.1mm) 3µm 2µm 2µm 0.5µm 40-0-40 2.0N or less
2901S-10 2901SB-10 0.001mm 0.16mm (0.2mm) 4µm 2µm 2µm 0.5µm 80-0-80 1.5N or less

* Completed products inspection is performed in the vertical position (contact point downward) and the stated accuracy is guaranteed.

Inch

Order No. Graduation Range (range/rev) Accuracy Repeat- ability Dial reading Measuring force
w/ lug Flat-back First 1 Rev / 2.5 Rev / 10 Rev Retrace
2909S-62 2909SB-62 .0005” .04” / .05” ±.0005” / — / — .00016” ±.0001” 20-0-20 2.5N or less
2910S-10 2910SB-10 .0001” .008” / .01” ±.0001” / — / — .0001” ±.00003” 4-0-4 1.8N or less

* Completed products inspection is performed in the vertical position (contact point downward) and the stated accuracy is guaranteed.

FEATURES

Metric

One Revolution Dial Indicators

Inch

One Revolution Dial Indicators

Graduation Dial Indicators

DIMENSIONS

Graduation Dial Indicators

Note 1: Dimensions of the inch (ANSI/AGD Type) dial indicator partly differ from those of the metric (ISO/ JIS Type) indicator.

Note 2: Inch (ANSI/AGD Type) dial indicators are provided with a stem of 3/8″ dia. and #4-48UNF thread mount for the contact point

Order No. A B C D E F G H I
2046S-60 48.8 70 57 17.7 20 12.3 29.2 52 7.6
2044S-60 48.8 70 57 17.7 20 12.3 29.2 52 7.6
2109S-70 48.8 65.3 57 17.7 20 12.3 24.5 52 7.6
2110S-70 48.8 67.5 57 17.7 20 12.3 26.7 52 7.6

SPECIFICATIONS
Metric

Order No. Graduation Range (range/rev) Accuracy Repeat- ability Dial reading Measuring force
w/ lug Flat-back Overall Retrace 1/10 Rev 1 Rev
2046S-60 2046SB-60 0.01mm 10mm (1mm) 13µm 3µm 5µm 10µm 3µm ±0-100 2.5N or less
2044S-60 2044SB-60 0.01mm 5mm (1mm) 12µm 3µm 5µm 10µm 3µm ±0-100 2.5N or less
2109S-70 2109SB-70 0.001mm 1mm (0.2mm) 5µm 2µm 2µm 4µm 0.5µm 0-100-0 2.0N or less
2110S-70 2110SB-70 0.001mm 1mm (0.1mm) 5µm 2µm 2µm 4µm 0.5µm ±0-100 2.0N or less

* Completed products inspection is performed in the vertical position (contact point downward) and the stated accuracy is guaranteed.

FEATURES
Metric

Graduation Dial Indicators

Standard Graduation Dial Indicators

DIMENSIONS

Standard Graduation Dial Indicators

Order No. A B C D E F G H I
2109S-10 48.8 60.5 57 17.7 20 16.9 15.1 52 7.6
2110S-10 48.8 66.5 57 17.7 20 16.9 21.1 52 7.6
2113S-10 48.8 61 57 17.7 20 16.9 15.6 52 7.6
2118S-10 48.8 60.3 57 17.7 20 16.9 14.9 52 7.6
2119S-10 48.8 60.3 57 17.7 20 16.9 14.9 52 7.6
2124S-10 48.8 60.3 57 17.7 20 16.9 14.9 52 7.6

SPECIFICATIONS
Metric

Order No. Graduation Range (range/rev) Accuracy Repeat- ability Dial reading Measuring force
w/ lug Flat-back Overall Retrace 1/10 Rev 1 Rev
2109S-10 2109SB-10 0.001mm 1mm (0.2mm) 5µm 2µm 2µm 4µm 0.5µm 0-100-0 1.5N or less
2110S-10 2110SB-10 0.001mm 1mm (0.1mm) 5µm 2µm 2µm 4µm 0.5µm ±0-100 1.8N or less
2113S-10 2113SB-10 0.001mm 2mm (0.2mm) 7µm 2µm 2µm 5µm 0.5µm 0-100-0 1.5N or less
2118S-10 2118SB-10 0.001mm 5mm (0.2mm) 10µm 3µm 3.5µm 6µm 1µm 0-100-100 1.5N or less
2119S-10 2119SB-10 0.001mm 5mm (0.2mm) 10µm 3µm 3.5µm 6µm 1µm 0-100-0 1.5N or less
2124S-10 2124SB-10 0.005mm 5mm (0.5mm) 12µm 3µm 5µm 9µm 3µm ±0-50 1.5N or less

* Completed products inspection is performed in the vertical position (contact point downward) and the stated accuracy is guaranteed.

FEATURES

Standard Graduation Dial Indicators

LCD Screen Indicator

SPECIFICATIONS
Metric

Order No.* Range Resolution Accuracy**
543-551 25mm

0.001mm, 0.01mm

0.003mm
543-557 50mm 0.003mm
543-553 50mm 0.006mm

* To denote your AC power cable add the following suffixes to the order No.: A for UL/CSA, D for CEE, DC for CCC, E for BS, K for KC, No suffix is required for JIS/100V
**Quantizing error of ±1 count is excluded.

Inch/Metric

Order No.* Range Resolution Accuracy**
543-552 1” /

25.4mm

.00005”, .0001”,

.0005”, .001”,

0.001mm, 0.01mm

.00012” /

0.003mm

543-558 2” /

50.8mm

.00012” /

0.003mm

543-554 2” /

50.8mm

.00024” /

0.006mm

*  To denote your AC power cable add the following suffixes to the order No.: A for UL/CSA, D for CEE, DC for CCC, E for BS, K for KC, No suffix is required for JIS/100V
**Quantizing  error of ±1 count is excluded.

DIMENSIONS

LCD Screen Indicator

Note 1: Dimensions of the inch (ANSI/AGD Type) dial indicator partly differ from those of the metric (ISO/JIS Type) indicator.
Note 2: Inch (ANSI/AGD Type) dial indicators are provided with a stem of 3/8″ dia. and #4-48UNF thread mount for the contact point.

Technical Data
Resolution: 0.01mm/0.001mm or .00005”/.0001”/.0005
”/.001”/0.001mm/0.01mm
Display: 6-digit LCD, sign, and analog bar with 2-color
backlight
Scale type: ABSOLUTE electrostatic linear encoder
Max. response speed: Unlimited
Measuring force: 1.8N or less (25.4mm models)
2.3N or less (50.8mm models)
Spindle orientation: Between the spindle pointing vertically
downward to the spindle horizontal
Stem dia.: 8mm (ISO/JIS type) or 3/8” (ANSI/AGD type)
Power supply: 9V DC (via AC adaptor) 06AEG302
Lifting lever: 137693
* To denote your AC power cable add the following
suffixes to the order No.: A for UL/CSA, D for CEE, DC
for CCC, E for BS, K for KC, No suffix is required for
JIS/100V

Functions
Preset, Zeroset, GO/±NG judgment, Max/Min value hold,
Runout measurement, Resolution switching,
Counting direction switching, Power ON/OFF, Data output,
inch/mm conversion (inch/mm models)
Alarm: Counting value composition error, Overflow
error, Tolerance limit setting error
Optional Accessories
• Lifting cable: No.540774 (stroke 25.4mm)
• Auxiliary spindle spring:
No.02ACA571 (25.4mm/1” models)*
No.02ACA773 (50.8mm/2” models)*
• Lug-on-center back:
No.101040 (ISO/JIS type)
No.101306 (ASME/ANSI/AGD type)
* Required when orienting the indicator upside down.
• SPC cable:
No.936937 (1m)
No.965014 (2m)
• USB Input Tool Direct (2m) : No.06ADV380F
• Connecting Cables for U-WAVE-T (160mm) :
No.02AZD790D
For footswitch: No.02AZE140D
Refer to page F-60 for details.
• Digimatic Mini-Processor DP-1VR: 264-504
• Contact points for Mitutoyo’s dial indicators *
• Interchangeable backs for Series 2 models*
• Measuring stands
* 4 Refer to pages F-46 to F-49 for details.
* 5 Refer to page F-50 for details.
Application
Difference/Runout measurement
Example: Indicator travel from points A to D
Difference (or Total Runout) is displayed as A. Dimensions B (maximum value) and C (minimum value) can be recalled from memory with a simple key sequence.

LCD Screen Indicator

Digimatic Indicator

Digimatic Indicator

SPECIFICATIONS
Metric

Order No.* Range Resolution Accuracy**
543-561 30.4mm 0.0005mm,

0.001mm

0.0015mm
543-563 60.9mm 0.0025mm

* To denote your AC power cable add the following suffixes to the order No.: A for UL/CSA, D for CEE, DC for CCC, E for BS, K for KC, No suffix is required for JIS/100V
** Quantizing error of ±1 count is excluded.

Inch/Metric

Order No.* Range Resolution Accuracy**
543-562 1.2” / 30.4mm .00002”,

.00005”, .0001”,

0.0005mm,

0.001mm

.00006” /

0.0015mm

543-564 2.4” / 60.9mm .0001” /

0.0025mm

* To denote your AC power cable add the following suffixes to  the order No.: A for UL/CSA, D for CEE, DC for CCC, E for BS, K for KC, No suffix is required for JIS/100V

DIMENSIONS

Digimatic Indicator

Note 1: Dimensions of the inch (ANSI/AGD Type) dial indicator partly differ from those of the metric (ISO/JIS Type) indicator.
Note 2: Inch (ANSI/AGD Type) dial indicators are provided with a stem of 3/8″ dia. and #4-48UNF thread mount for the contact point.
( ): for 30.4mm model

Digimatic Indicator

Technical Data
Display: 7-digit LCD, sign, and analog bar with 2-color backlight
Power supply: 6V DC (via AC adaptor) 06AEG180
* To denote your AC power cable add the following suffixes to the
order No.: A for UL/CSA, D for CEE, DC for CCC, E for BS, K for KC,
No suffix is required for JIS/100V
Positional detection method: Photoelectric-type reflection linear encoder
Maximum response speed: 1000mm/sec
Measuring force: 2.0N or less (30.4mm/1.2″type)
2.5N or less (60.9mm/2.4″type)
Spindle orientation: Between the spindle pointing vertically
downward to the spindle horizontal
Standard contact point: 901312 (ISO/JIS type)
21BZB005 (ANSI/AGD type)
Lifting lever: No.137693

Functions
Zero set, Preset, GO/±NG judgement
Max/Min value hold, Runout measurement
Resolution switching
Counting direction switching
Data output, Data hold, Function lock
inch/mm conversion (inch/mm models)
Alarm: Over speed error, Setting error, Overflow error

Optional accessories
• Lifting
Lifting knob : No.21EZA101
Lifting cable : No.540774 (stroke 30 mm)
• Lug-on-center back:
No.101040 (ISO/JIS type)
No.101306 (ASME/ANSI/AGD type)
• Remote controller : No.21EZA099
• RS-232 Connecting cable (2m) : No.21EAA131
• SPC Cable:
No.936937 (1m)
No.965014 (2m)
• USB Input Tool Direct (2m) : No.06ADV380D
• Connecting Cables for U-WAVE-T (160mm) :
No.02AZD790D
For footswitch : No.02AZE140D
Refer to page F-60 for details.
• Digimatic Mini-Processor DP-1VR: 264-504
• Contact points for Mitutoyo’s dial indicators (Refer to pages F-46 to F-49 for details.)
• Granite comparator stand: 215-156-10
• Comparator stand: 215-505-10

Absolute Digimatic Indicator

SPECIFICATIONS
Metric

Order No. (w/ lug, flat-back) Range Resolution Accuracy* Measuring force
575-121 25.4mm 0.01mm 0.02mm 1.8N or less

Inch/Metric

Order No. (w/ lug, flat-back) Range Resolution Accuracy* Measuring force
575-122 1” / 25.4mm .0005”/0.01mm .001” / 0.02mm 1.8N or less
575-123

*Quantizing error of ±1 count is excluded
*Flat back only

DIMENSIONS

Absolute Digimatic Indicator

Note 1: Dimensions of the inch (ANSI/AGD Type) dial indicator partly differ from those of the metric (ISO/JIS Type) indicator.
Note 2: Inch (ANSI/AGD Type) dial indicators are provided with a stem of 3/8″ dia. and #4-48UNF thread mount for the contact point.

Technical Data
Accuracy: Refer to the list of specifications (Excluding quantizing error of ±1 count)
Resolution: 0.01mm, .0005″/0.01mm
Display: 5-digit and sign
Scale type: ABSOLUTE electrostatic linear encoder
Max. response speed: Unlimited (Measurement by scanning cannot be performed)
Measuring force: Refer to the list of specifications
Stem dia.: 8mm (ISO/JIS type) or 3/8” (ANSI/AGD type)
Standard contact point: 901312 (ISO/JIS type)
21BZB005 (ANSI/AGD type)
Battery: SR44 (1 pc.), 938882 for initial
operational checks (standard accessory)
Battery life: Approx. 20,000 hours of continuous use
Dust/Water protection level: IP42
Lifting lever: 137693

Function
Origin-set (Zeroset), Counting direction switching,
Power ON/OFF, Data output,
inch/mm conversion (inch/mm models)
Alarm: Low voltage, Counting value composition error

Optional Accessories
• Spindle lifting cable (stroke: 10mm) : No.540774
• SPC Cable:
No.905338 (1m)
No.905409 (2m)
• USB Input Tool Direct (2m) : No.06ADV380F
• Connecting Cables for U-WAVE-T (160mm):
No.02AZD790F
For footswitch : No.02AZE140F
Refer to page F-60 for details.
• Digimatic Mini-Processor DP-1VR: 264-504
• Contact points for Mitutoyo’s dial indicators (Refer to pages F-46 to F-49 for details.)
• Measuring stands (Refer to page F-79 to F-85 for details.)

Signal Output Digimatic Indicator

SPECIFICATIONS
Metric

Order No. (w/ lug, flat-back) Range Resolution Accuracy*2 Measuring force
543-350 543-350B 12.7mm 0.001/0.01mm 0.003mm or less 2.5N or less

Inch/Metric

Order No. (w/ lug, flat-back) Range Resolution Accuracy*2 Measuring force
543-351 543-351B .5” / 12.7mm .00005/.0001/.0005” //

0.001/0.01mm

±.00010” / 0.003mm or less 2.5N or less
543-352 543-352B

Notes:
1) LCD readout does not rotate.
2) Max./min. holding: sample rate is 100 readings/sec; max. rate of change of reading is 100μm/sec.
3) Products with an Order No. suffixed “B” have a flat back
4) Standard contact point: 901312 (ISO/JIS type), 21BZB005 (ANSI/AGD type)
*2 Quantizing error of ±1 count is excluded.

DIMENSIONS

Signal Output Digimatic Indicator

Note 1: Dimensions of the inch (ANSI/AGD Type) dial indicator partly differ from those of the metric (ISO/JIS Type) indicator.
Note 2: Inch (ANSI/AGD Type) dial indicators are provided with a stem of 3/8″ dia. and #4-48UNF thread mount for the contact point.

Functions
Signal output (–NG/OK/+NG, N-ch open drain, logical invert is available), Remote control (peak start preset/zero-set),Preset, Zeroset, GO/±NG judgment (3 pairs of ABS, INC memory function) Max/Min/Runout value holding, Measurement direction switching, Power ON/OFF, inch/mm conversion (inch/mm models), Resolution switching, Scaling function f(x)=Ax, Key lock, Calibration mode (Signal output in Digimatic code format).
Alarm: Counting value composition error, Overflow error, Tolerance limit setting error
Optional accessories
• Lifting* 3
Lifting lever No.21EZA198 (ISO/JIS/DIN Type),
No.21EZA199 (ASME/ANSI/ AGD Type)
Lifting knob No.21EZA105 (ISO/JIS/DIN Type),
No.21EZA150 (ASME/ANSI/ AGD Type)
Lifting cable No.540774
• Digimatic power unit: 21EZA345
Note: To denote your AC power cable add the following
suffixes to the order No.: A for UL/CSA, D for
CEE, DC for CCC, E for KC. No suffix is required
for JIS/100VAC.
Used in the calibration mode when executing
automatic inspection using i-Checker.
In such a case, please purchase connecting cable
21EAA194 (1m), or 21EAA190 (2m).
• Contact points for Mitutoyo’s dial indicators.*
• Interchangeable backs for Series 2 models. Dust-water
protection is not guaranteed. Use the waterproof types
of Series 2 for plain backs if required.*5
• Measuring stands (Refer to page F-75 to F-80 for details.
*3 Dust-water protection is not guaranteed.
*4 Refer to pages F-46 to F-49 for details.
*5 Refer to page F-50 for details.

Output signals and LCD display

Wire – NG OK + NG Composition error
Orange (– NG) Low High High High
Green (OK) High Low High High
Brown (+ NG) High High Low High
LCD “x.xxE” indication

* Logical invert is available.

I/O Specifications

Wire Signal I/O Description
Black – V (GND) Connected to minus (-)

terminal

Red + V Power  supply (5 – 24VDC)
Orange – NG O Tolerance judgment

result output: Only the

terminal corresponding to

a judgment result is set to

the low level.

Green OK O
Brown + NG O
Yellow PRESET_RECALL

ZERO

I External input terminal: If

the relevant terminal is set

to the low level, its signal

becomes true.

Blue PEAK_START I
Shield FG Connected to GND (Earth)

Note: Measurement data cannot be output.

Signal Output Digimatic Indicator

Calculation Type Digimatic Indicator

SPECIFICATIONS
Metric

Order No.* Range Resolution (selectable) Accuracy*1 Hysteresis*1 Repeatability*1 Measuring force Power supply Battery life (normal use)*2 Net weight
543-340B 12.7mm 12 steps*5 0.003mm 0.002 mm 0.002 mm 1.5N or less CR2032 x 1 pc. Approx. 1 year 170 g
543-590B 25.4mm 1.8N or less*3 190 g
543-595B 50.8mm 0.006mm 2.3N or less*3 260 g

* Flat back only
Inch/Metric

Order No.* Resolution (selectable) Range Accuracy*1 Hysteresis*1 Repeatability*1 Measuring force Power supply Battery life (normal use)*2 Net weight
543-341B

12 steps*5

.5″/12.7mm

±.00010″ / 0.003 mm

.00010″ /

0.002 mm

00010″ /

0.002 mm

1.5N or less

CR2032 x 1 pc.

Approx. 1 year

170 g
543-342B
543-591B 1”/25.4mm 1.8N or less*3 190 g
543-592B
543-596B 2”/50.8mm ±.00025″ / 0.006 mm 2.3N or less*3 260 g
543-597B

* Flat back only
Note: All instruments in this series are of the flat back type.
The back is interchangeable with the standard backs for Series 2.
Refer to page F-55 for details of the optional backs.
*1 Does not include quantizing error (±1 count). Valid for resolution set to 0.001mm/’.00005″ and coefficients A=1, B=0 and C=0.
*2 Applies only if not connected to a data processor. Battery life depends on use of the indicator. Use the above value as a guide
only. (TIP) Battery life with Peak detection mode and FAST mode ON is about 10 months.
*3 Applies for a spindle orientation between the spindle pointing vertically downward to the spindle horizontal.
*4 The resolution can be selected from one of 12 steps (Refer to table right).

DIMENSIONS

Calculation Type Digimatic Indicator

Note 1: Dimensions of the inch (ANSI/AGD Type) dial indicator partly differ from those of the metric (ISO/JIS Type) indicator.
Note 2: Inch (ANSI/AGD Type) dial indicators are provided with a stem of 3/8″ dia. and #4-48UNF thread mount for the contact point.

Fixture examples

Calculation Type Digimatic Indicator

Examples of measuring various features 

Calculation Type Digimatic Indicator

* The spindle position at which the ORIGIN is set. This is when the contact point is touching either the reference plane or the calibrated artefact, as shown.
** The ‘Err30’ message shown in the display is extinguished when the spindle is moved into the measurement range.
*** The value of d is chosen to suit the radius range to be measured, the stroke of the indicator and the best spindle position for the ORIGIN. Note that the value of x’ should not be allowed  to approach zero as this is a highly non-linear region of the equation and measurement accuracy will deteriorate rapidly. A spreadsheet simulation will aid selection of the best value of d for particular r, L and R values.
Notes
1. Fixtures suited to individual workpieces can be made to order.
2. Measuring accuracy is subject to fixture accuracy and workpiece form accuracy.

Functions

Calculation function f (x’) = Ax’ + B + Cx’
(x’ = x + offset)
Peak detection function (Max/Min)
Runout value Hold function (difference between max.
and min. value motion)
Peak detection sampling rate (Switchable)
10 times/sec. (FAST Mode OFF)
50 times/sec. (FAST Mode ON)
Zeroset function (INC system)
Preset function (ABS system)
Tolerance judgement function (P1, P2, P3, and INC can be stored)
Analog bar resolution selectable function
Key lock function
Display hold function (when external device is connected)
Data output function
External PC setting input function (330°)
Low battery/voltage alarm display
Error alarm display
Resolution switching function*

Resolution (mm)

0.0002 0.005 0.1
0.0005 0.01 0.2
0.001 0.02 0.5
0.002 0.05 1

Resolution (inch)

0.00001 0.0002 0.005
0.00002 0.0005 0.01
0.00005 0.001 0.02
0.0001 0.002 0.05

*5: Since the calculation resolution is one micrometer
(0.001mm), using sub-micrometer resolution settings
may result in the 4th-place digit being unreliable,
particularly when B is set to a very low value
and C =0. It does not change at all with certain
combinations of calculation coefficient (for example,
A = 1, B = C =0). The 3rd-place digit representing
micrometers (if displayed) is always reliable.

Optional Accessories

• Lifting
Lifting lever:
No.21EZA198 (ISO/JIS/DIN Type),
No.21EZA199 (ASME/ANSI/ AGD Type)
Lifting knob:
No.21EZA105 (ISO/JIS/DIN Type),
No.21EZA150 (ASME/ANSI/ AGD Type)
Lifting cable : No. 540774
• SPC Cable:
No.905338 (1m)
No.905409 (2m)
• USB Input Tool Direct (2m) : No.06ADV380F
• Connecting Cables for U-WAVE-T (160mm) :
No.02AZD790F
For footswitch : No.02AZE140F
Refer to page F-60 for details.
• Digimatic Mini-Processor DP-1VR : 264-504
• Parameter setup kit : No.21EZA313
Note: Parameter setting software (can be downloaded  freely from Mitutoyo website) is also required.
• Contact points for Mitutoyo’s dial indicators (Refer to pages F-51 to F-54 for details.)
• Measuring stands (Refer to page F-79 to F-85 for details.)

Bore Gage Type Digimatic Indicator

SPECIFICATIONS
Metric

Order No.* Range Resolution Accuracy*1 Hysteresis*1 Repeatability*1 Power supply Battery life (normal use)*2 Net weight
543-310B 12.7mm 0.001/0.01mm 0.003mm 0.002 mm 0.002 mm CR2032

x 1 pc.

Approx. 1 year 170 g

*Flat back only

Inch/Metric

Order No.* Range Resolution Accuracy*1 Hysteresis*1 Repeatability*1 Power supply Battery life (normal use)*2 Net weight
543-311B

.5″/12.7mm

.00005/.0001/.0005″/

0.001/0.01 mm

±.00010″ / 0.003 mm

.00010″ /

0.002 mm

.00010″ /

0.002 mm

CR2032 x 1 pc.

Approx. 1 year

170 g

543-312B

*Flat back only

*1 Does not include quantizing error (±1 count). Valid for resolution set to 0.001mm/.00005″
*2 Applies only if not connected to a data processor. Battery life depends on use of the indicator. Use the above value as a guide only. (TIP) Battery life with Peak detection mode and FAST mode ON is about 4.5 months.
Notes:
1) Min. hold: sample rate is 50 readings/sec; maximum trackable rate of change is 50μm/sec.
2) All instruments in this series are of the flat back type.
3) All instruments in this series can be only used for inside diameter measurement.

DIMENSIONS

Bore Gage Type Digimatic Indicator

Note 1: Dimensions of the inch (ANSI/AGD Type) dial indicator partly differ from those of the metric (ISO/JIS Type) indicator.
Note 2: Inch (ANSI/AGD Type) dial indicators are provided with a stem of 3/8″ dia. and #4-48UNF thread mount for the contact point.

Functions
Minimum value detection function
Preset function (3 Preset values can be stored)
Tolerance judgement function (3 sets of upper and lower
limits can be stored)
Resolution selection function
Analog bar resolution selection function
Key lock function
in/mm conversion (when external device is connected)
Display hold function (when external device is connected)
Data saving/calling function (when external device is connected)
Data output function
External PC setting input function
Display rotation function
Low battery/voltage alarm display
Error alarm display

Optional Accessories
• SPC Cable:
No.905338 (1m)
No.905409 (2m)
• USB Input Tool Direct (2m) : No.06ADV380F
• Connecting Cables for U-WAVE-T (160mm) :
No.02AZD790F
For footswitch : No.02AZE140F
Refer to page F-60 for details.
• Digimatic Mini-Processor DP-1VR: 264-504
• Parameter setup kit : No.21EZA313
Note: Parameter setting software (can be downloaded freely from Mitutoyo website) is also required.

The ABSOLUTE Digimatic Bore Gage

Bore Gage Type Digimatic Indicator

ABSOLUTE Digimatic Bore Gages, which integrate the display with a bore gage measuring unit, are also available.
Refer to pages C-41 and C-42 for details.

Bore Gage Type Digimatic Indicator