Call Us: +91-7972969901
Call Us: +91-7972969901
| Order no. | Measuring range mm | Measuring range inches | Resolution | Resolution | Error limit inches | Error limit µm | Product weight | Standard | Data interface |
|---|---|---|---|---|---|---|---|---|---|
| 4426100 |
0 – 350
|
0 – 14″
|
0.01 mm
|
0.001 inch
|
.0016″
|
40 µm
|
7 kg
|
Factory standard
|
Opto RS232C / Digimatic / USB / Wireless
|
| 4426101 |
0 – 600
|
0 – 24″
|
0.01 mm
|
0.001 inch
|
.0020″
|
50 µm
|
8 kg
|
Factory standard
|
Opto RS232C / Digimatic / USB / Wireless
|
| Order no. | Measuring range mm | Measuring range inches | Resolution | Resolution | Error limit inches | Error limit µm | Perpendicularity error in µm | Measuring force | Product weight | Standard | Data interface |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 4426540 |
0 – 320
|
0 – 12.6″
|
0.001 mm / 0.01 mm
|
0 inch / 0.001 inch
|
.0008″
|
20 µm
|
20 µm
|
3 N
|
6.2 kg
|
Factory standard
|
Opto RS232C / Wireless
|
| 4426542 |
0 – 620
|
0 – 24.4″
|
0.001 mm / 0.01 mm
|
0 inch / 0.001 inch
|
.0012″
|
30 µm
|
30 µm
|
3 N
|
10.5 kg
|
Factory standard
|
Opto RS232C / Wireless
|
| Order no. | Measuring range mm | Measuring range inches | Resolution | Resolution | Error limit inches | Error limit µm | Perpendicularity error in µm | Measuring force | Product weight | Standard | Data interface |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 4426541 |
0 – 320
|
0 – 12.6″
|
0.001 mm / 0.01 mm
|
0 inch / 0.001 inch
|
.0008″
|
20 µm
|
20 µm
|
3 N
|
14 kg
|
Factory standard
|
Opto RS232C / Wireless
|
| 4426543 |
0 – 620
|
0 – 24.4″
|
0.001 mm / 0.01 mm
|
0 inch / 0.001 inch
|
.0012″
|
30 µm
|
30 µm
|
3 N
|
18.3 kg
|
Factory standard
|
Opto RS232C / Wireless
|
SPECIFICATIONS
Metric
| Order No. | Range | Resolution | Fine feed | Accuracy* | Repeatability | Height | Mass |
|---|---|---|---|---|---|---|---|
| 570-227 | 0 – 200mm | 0.01mm | 4mm | ±0.03mm | 0.01mm | 355mm | 1.4kg |
| 570-230 | 0 – 1000mm | 6mm | ±0.07mm | 1260mm | 16.8kg |
* Excluding quantizing error
Inch/Metric
| Order No. | Range | Resolution | Fine feed | Accuracy* | Repeatability | Height | Mass |
|---|---|---|---|---|---|---|---|
| 570-244 | 0 – 8″ | .0005″ /0.01mm | .16” | ±.002″ | 0.01mm | 355mm | 1.4kg |
| 570-248 | 0 – 40″ | .24” | ±.003″ | 1260mm | 16.8kg |
* Excluding quantizing error
DIMENSIONS
Functions
Zero-setting
+/- directional measurement
Data hold
Data output
Presetting
inch/mm reading (inch/mm models)
Preset value memory
Origin restoration
Low battery voltage alert
Counting value composition error alert
Optional accessories
For details, refer to page D-39.
Connecting cables for IT/DP/MUX
905338: SPC cable with data button (1m)
905409: SPC cable with data button (2m)
USB Input Tool Direct
06ADV380F: SPC cable for USB-ITN-F (2m)
Connecting cables for U-WAVE-T
02AZD790F: SPC cable for U-WAVE with data button (160mm)
02AZE140F: SPC cable for footswitch

SPECIFICATIONS
Metric
| Order No. | Range | Resolution | Accuracy* | Repeatability | Max. response speed | Mass |
|---|---|---|---|---|---|---|
| 570-302 | 0 – 300mm | 0.01mm | ±0.03mm | 0.01mm | Unlimited | 4.6kg |
| 570-304 | 0 – 600mm | ±0.05mm | 6.4kg |
* Excluding quantizing error
Inch/Metric
| Order No. | Range | Resolution | Accuracy* | Repeatability | Max. response speed | Mass |
|---|---|---|---|---|---|---|
| 570-312 | 0 – 12″ |
.0005″/0.01mm |
±.0015″ |
0.01mm |
Unlimited |
4.6kg |
| 570-313 | 0 – 18″ | ±.002″ | 5.9kg | |||
| 570-314 | 0 – 24″ | ±.002″ | 6.4kg |
* Excluding quantizing error
DIMENSIONS
( ): No. 570-304
Functions
Origin-setting:
Any convenient reference surface, such as a surface plate, etc., can be stored as the absolute origin point.
Absolute measurement:
After power is turned ON, measurement can be started without zero-setting if origin-setting was previously performed. Absolute origin position can be changed by ORIGIN button.
Incremental measurement:
Allows origin setting at any arbitrary position. In this case, the origin point is not stored after turning off the power.
Data hold
Display value can be held.
Data output:
Allows integration into statistical process control and measurement systems. (Refer to page A-3.)
Low-voltage alert:
Low-voltage alert: If the battery voltage becomes low, a “B” appears in the display to alert the user before measurement is no longer possible so that the battery can be changed in good time.
Standard accessories
For 570-302, 304
No.07GZA000 Scriber
No.05GZA033 Scriber clamp
For 570-312 and 570-313, 570-314
No.900258 Scriber
No.901385 Scriber clamp
Optional accessories
For details, refer to page D-39. Connecting cables for IT/DP/MUX
905338: SPC cable with data button (1m) 905409: SPC cable with data button (2m)
USB Input Tool Direct
06ADV380F: SPC cable for USB-ITN-F (2m)
Connecting cables for U-WAVE-T
02AZD790F: SPC cable for U-WAVE with data button (160mm)
02AZE140F: SPC cable for footswitch