Call Us: +91-7972969901
Call Us: +91-7972969901

SPECIFICATIONS
Metric
| Order No. | Range | Resolution | Accuracy* | Repeatability | Max. response speed | Mass |
|---|---|---|---|---|---|---|
| 570-302 | 0 – 300mm | 0.01mm | ±0.03mm | 0.01mm | Unlimited | 4.6kg |
| 570-304 | 0 – 600mm | ±0.05mm | 6.4kg |
* Excluding quantizing error
Inch/Metric
| Order No. | Range | Resolution | Accuracy* | Repeatability | Max. response speed | Mass |
|---|---|---|---|---|---|---|
| 570-312 | 0 – 12″ |
.0005″/0.01mm |
±.0015″ |
0.01mm |
Unlimited |
4.6kg |
| 570-313 | 0 – 18″ | ±.002″ | 5.9kg | |||
| 570-314 | 0 – 24″ | ±.002″ | 6.4kg |
* Excluding quantizing error
DIMENSIONS
( ): No. 570-304
Functions
Origin-setting:
Any convenient reference surface, such as a surface plate, etc., can be stored as the absolute origin point.
Absolute measurement:
After power is turned ON, measurement can be started without zero-setting if origin-setting was previously performed. Absolute origin position can be changed by ORIGIN button.
Incremental measurement:
Allows origin setting at any arbitrary position. In this case, the origin point is not stored after turning off the power.
Data hold
Display value can be held.
Data output:
Allows integration into statistical process control and measurement systems. (Refer to page A-3.)
Low-voltage alert:
Low-voltage alert: If the battery voltage becomes low, a “B” appears in the display to alert the user before measurement is no longer possible so that the battery can be changed in good time.
Standard accessories
For 570-302, 304
No.07GZA000 Scriber
No.05GZA033 Scriber clamp
For 570-312 and 570-313, 570-314
No.900258 Scriber
No.901385 Scriber clamp
Optional accessories
For details, refer to page D-39. Connecting cables for IT/DP/MUX
905338: SPC cable with data button (1m) 905409: SPC cable with data button (2m)
USB Input Tool Direct
06ADV380F: SPC cable for USB-ITN-F (2m)
Connecting cables for U-WAVE-T
02AZD790F: SPC cable for U-WAVE with data button (160mm)
02AZE140F: SPC cable for footswitch


SPECIFICATIONS
Metric
| Order No. | Range | Resolution | Accuracy* | Repeatability | Max. response speed | Height | Mass |
|---|---|---|---|---|---|---|---|
| 192-613-10 | 0 – 300mm | 0.01mm
(0.005mm) |
±0.02mm | 0.01mm | 500mm/s | 475mm | 4.7kg |
| 192-614-10 | 0 – 600mm | ±0.05mm | 802mm | 8.3kg | |||
| 192-615-10 | 0 – 1000mm | ±0.07mm | 1228mm | 15.7kg |
* Excluding the quantizing error of ±1 count.
Inch/Metric
| Order No. | Range | Resolution | Accuracy* | Repeatability | Max. response speed | Height | Mass |
|---|---|---|---|---|---|---|---|
| 192-630-10 | 0 – 12″ |
.0005″/0.01mm (.0002″ /0.005mm) |
±.001″ |
0.01mm |
500mm/s |
475mm | 4.7kg |
| 192-631-10 | 0 – 18″ | ±.002″ | 649mm | 7.5kg | |||
| 192-632-10 | 0 – 24″ | ±.002″ | 802mm | 8.3kg | |||
| 192-633-10 | 0 – 40″ | ±.003″ | 1228mm | 15.7kg |
* Excluding the quantizing error of ±1 count.
DIMENSIONS
Order No. 192-613-10, 192-614-10 ( ): No. 192-614-10
Order No. 192-615-10
Functions
Origin-setting (ABS measurement mode):
Any arbitrary value can be stored as the origin point. Zero-setting (INC measurement mode): Displayed value can be set to zero at any arbitrary position of the slider.
Origin restoration:
Previously set origin is restored when switching back to ABS mode.
Presetting (ABS INC measurement mode):
Displayed value can be set to any arbitrary value, including negative values.
Measuring direction
Measuring direction can be switched at the press of a button.
Data hold
Display value can be held. Reverts to ABS or INC mode when cancelled.
Alarm:
Error message is displayed when overflow or overspeed of displayed value arises and measurement is stopped.
Data output:
Allows integration into statistical process control and measurement systems. (Refer to page A-3.) Fine and coarse height adjustment through knob and wheel combination.
Slider height adjustment wheel allows fine and coarse height adjustment.
Low-voltage alert:
When battery voltage becomes low, a warning appears in the display.
Probe-tip diameter compensation:
An adjustment is applied to the raw measurement data to compensate for the effect of the size of the spherical contact point used by the bidirectional touch-trigger probe.
Presetting (2 positions)
With two preset functions, two reference heights can be used relative to a surface plate.
* Probe-tip-diameter compensation mode is a function provided for Order No. 192-663-10/192-664-10/192-665-10/192-670-10/ 192-671-10/192-672-10/192-673-10.

SPECIFICATIONS
Metric
| Order No. | Range | Resolution | Accuracy* | Repeatability | Max. response speed | Height | Mass |
|---|---|---|---|---|---|---|---|
| 192-663-10 | 0 – 300mm | 0.01mm
(0.005mm) |
±0.02mm |
0.01mm |
500mm/s | 510mm | 5.7kg |
| 192-664-10 | 0 – 600mm | ±0.04mm | 802mm | 8.3kg | |||
| 192-665-10 | 0 – 1000mm | ±0.06mm | 1228mm | 15.7kg |
* Excluding quantizing error
Inch/Metric
| Order No. | Range | Resolution | Accuracy* | Repeatability | Max. response speed | Height | Mass |
|---|---|---|---|---|---|---|---|
| 192-670-10 | 0 – 12″ |
.0005″/0.01mm (.0002″ /0.005mm) |
±.001″ |
0.01mm |
500mm/s |
510mm | 5.7kg |
| 192-671-10 | 0 – 18″ | ±.0015″ | 649mm | 7.5kg | |||
| 192-672-10 | 0 – 24″ | ±.0015″ | 802mm | 8.3kg | |||
| 192-673-10 | 0 – 40″ | ±.0025″ | 1228mm | 15.7kg |
* Excluding quantizing error
Functions
Origin-setting (ABS measurement mode): Any arbitrary value can be stored as the origin point.
Zero-setting (INC measurement mode): Displayed value can be set to zero at any arbitrary position of the slider.
Origin restoration: Previously set origin is restored when switching back to ABS mode.
Presetting (ABS INC measurement mode): Displayed value can be set to any arbitrary value, including negative values.
Measuring direction
Measuring direction can be switched at the press of a button.Data hold Display value can be held. Reverts to ABS or INC mode when cancelled.
Alarm: Error message is displayed when overflow or overspeed of displayed value arises and measurement is stopped.
Data output: Allows integration into statistical process control and measurement systems. (Refer to page A-3.)
Fine and coarse height adjustment through knob and wheel combination.
Slider height adjustment wheel allows fine and coarse height adjustment.

Coarse adjustment Fine adjustment
Push the small fine-adjustment knob in to disengage gearing and then turn the large wheel.
Pull the fine-adjustment knob out to engage gearing and then turn this knob, which then slowly turns the wheel.
Low-voltage alert: When battery voltage becomes low, a warning appears in the display.

* Probe-tip-diameter compensation mode is a function provided for Order No. 192-663-10/192-664-10/192-665-10/192-670-10/ 192-671-10/192-672-10/192-673-10.
Probe-tip diameter compensation: An adjustment is applied to the raw measurement data to compensate for the effect of the size of the spherical contact point used by the bidirectional touch-trigger probe.
Presetting (2 positions)
With two preset functions, two reference heights can be used relative to a surface plate.
DIMENSIONS

Order No. 192-663-10, 192-664-10 ( ): No. 192-664-10

Order No. 192-665-20
Optional Accessory
Bidirectional touch-trigger probe
Improves accuracy in step, internal thickness, and outside width measurement by minimizing reproducibility error.

SPECIFICATIONS
Metric
| Order No. | Measuring direction | Relay contact type | Probe overtravel | Probe size | Repeatability | Measuring force | Standard accessories |
|---|---|---|---|---|---|---|---|
| 192-007 | Bidirectional | Normally Open | 1.5mm | ø3mm | : 2μm | 0.4N | Holder arm, Clamp |
Inch
| Order No. | Measuring direction | Relay contact type | Probe overtravel | Probe size | Repeatability | Measuring force | Standard accessories |
|---|---|---|---|---|---|---|---|
| 192-008 | Bidirectional | Normally Open | 1.5mm | ø3mm | : 2μm | 0.4N | Holder arm, Clamp |
For details of the connecting cable, refer to page D-39.
Connecting cables for IT/DP/MUX
905338: SPC cable (1m)
905409: SPC cable (2m)
USB Input Tool Direct
06ADV380F: SPC cable for USB-ITN-F (2m)
Connecting cables for U-WAVE-T
02AZD790F: SPC cable for U-WAVE (160mm)
02AZE140F: SPC cable for footswitch
| Code | For Height Gages | Type | c1 | c2 | D | E |
| 7150-SC1 | 1150-300 | A | 76 | 25 | 6 | 8 |
| 7150-SC2 | 1150-500, 1150-600 | A | 103 | 25 | 10 | 12 |
| 7150-SC3 | 1150-1000, 1150-1500, 1150-2000 | A | 110 | 39 | 10 | 15 |
| 7150-SC4 | 1151-300, 1151-450, 1151-600, 1351-300, 1351-450, 1351-600 | B | 48 | 15 | 9 | 9 |
| 7150-SC6 | 1250-300 | A | 80 | 30 | 9 | 9 |
| 7150-SC7 | 1250-450, 1250-600 | A | 80 | 41 | 9 | 9 |
| 7150-SC8 | 1250-1000 | A | 204 | 50 | 10 | 16 |
| 7150-SC9 | 1253-150, 1253-200, 1154-150 | B | 55 | 12.5 | 6 | 8 |
![]() |
![]() |
![]() |
| Code | Range | Accuracy | L | a1 | a2 | b | c1 | c2 | d |
| 1250-300 | 0-300mm/0-12″ | ±0.04mm | 545 | 135 | 43 | 75 | 80 | 30 | 28 |
| 1250-450 | 0-450mm/0-18″ | ±0.05mm | 720 | 180 | 54 | 85 | 80 | 41 | 35 |
| 1250-600 | 0-600mm/0-24″ | ±0.05mm | 870 | 180 | 54 | 85 | 80 | 41 | 35 |