Long Jaw Vernier Caliper

SPECIFICATIONS

Metric with inside measurement vernier scale

Order No. Range* Accuracy Graduation Remarks
534-113 0 (10.1) – 300mm ±0.04mm

0.02mm

with fine adjustment

534-114 0 (20.1) – 500mm ±0.06mm
534-115 0 (20.1) – 750mm ±0.08mm
534-116 0 (20.1) – 1000mm ±0.10mm

* ( ): Minimum dimension in inside measurement

Inch with inside measurement vernier scale

Order No. Range* Accuracy Graduation Remarks
534-117 0 (.304”) – 12″ ±.002″

.001”

with fine adjustment

534-118 0 (.804”) – 20″ ±.003″
534-119 0 (.804”) – 30″ ±.004″
534-120 0 (.804”) – 40″

* ( ): Minimum dimension in inside measurement

DIMENSIONS

Long Jaw Vernier Caliper

Long Jaw Vernier Caliper

Offset Caliper

SPECIFICATIONS

Metric Digital model

Order No. Range Accuracy
573-601 0 – 150mm ±0.02mm
573-611* 0 – 150mm ±0.02mm
573-602 0 – 200mm ±0.02mm
573-612* 0 – 200mm ±0.02mm
573-604 0 – 300mm ±0.03mm
573-614* 0 – 300mm ±0.03mm

* Without thumb roller

Inch/Metric Digital model

Order No. Range Accuracy
573-701 0 – 6″ ±.001″
573-702 0 – 8″ ±.001″
573-704 0 – 12″ ±.0015″

Metric Analog model

Order No. Range Accuracy
536-101 0 – 150mm ±0.05mm
536-102 0 – 200mm ±0.05mm
536-103 0 – 300mm ±0.08mm

DIMENSIONS

Offset Caliper

Order No. Model Range D G J N W
573-601 Digital model 0 – 150mm 40 10 30 10 95
573-602 0 – 200mm 50 10 38.5 10 95
573-604 0 – 300mm 64 15 51 15 135
536-101 Analog model 0 – 150mm 40 10 30 10 95
536-102 0 – 200mm 50 10 38.5 10 95
536-103 0 – 300mm 64 15 51 15 135

Offset Caliper

Technical Data
Accuracy: Refer to the list of specifications.

(excluding quantizing error for digital models)
Resolution*: 0.01mm or .0005″/0.01mm Graduation**: 0.05mm
Display*:    LCD
Scale type*: ABSOLUTE electromagnetic induction linear encoder
Max. response speed*: Unlimited
Battery: SR44 (1 pc), 938882, for initial operational checks (standard accessory)
Battery life*: Approx. 3 years under normal use (1 year: 300mm model)
Dust/Water protection level*: IP67 (IEC 60529)***
* Digital models
** Analog models
*** This model is not waterproof type.
Therefore, rustproofing shall be applied after use.

Optional accessories for Digital Model
For details, refer to page D-39.

959143: Data hold unit Connecting cables for IT/DP/MUX
05CZA624: SPC cable with data button (1m)
05CZA625: SPC cable with data button (2m)

USB Input Tool Direct
06ADV380A: SPC cable for USB-ITN-A (2m)

Connecting cables for U-WAVE-T
02AZD790A: SPC cable for U-WAVE with data button (160mm)

02AZE140A: SPC cable for footswitch

Long Jaw Caliper

SPECIFICATIONS

Metric with inside measurement vernier scale

Order No. Range* Accuracy Graduation Remarks
534-109 0 (10.1) – 300mm ±0.07mm 0.05mm without fine adjustment
534-110 0 (20.1) – 500mm ±0.13mm

* ( ): Minimum dimension in inside measurement

Metric/Inch with metric/inch double scale

Order No. Range* Accuracy Graduation Remarks
534-101 0 (10.1) – 300mm ±0.07mm 0.05mm/ 1/128” +10mm/.394” to reading in inside measurement without fine adjustment
534-105 ±0.04mm 0.02mm/.001”
534-102 0 (20.1) – 500mm ±0.13mm 0.05mm/ 1/128”

+20mm/.787” to reading in inside measurement without fine adjustment

534-106 ±0.06mm 0.02mm/.001”
534-103 0 (20.1) – 750mm ±0.16mm 0.05mm/ 1/128”
534-107 ±0.08mm 0.02mm/.001”
534-104 0 (20.1) – 1000mm ±0.20mm 0.05mm/ 1/128”
534-108 ±0.10mm 0.02mm/.001”

* ( ): Minimum dimension in inside measurement

Long Jaw Caliper

Carbon Fiber Caliper

SPECIFICATIONS

Metric

Order No. Range Accuracy
552-181-10 0 – 450mm ±0.04mm
552-182-10 0 – 600mm
552-183-10 0 – 1000mm ±0.05mm
552-184-10 0 – 1500mm ±0.09mm
552-185-10 0 – 2000mm ±0.12mm

Inch/Metric

Order No. Range Accuracy
552-191-10 0 – 18″

±.002″

552-192-10 0 – 24″
552-193-10 0 – 40″
552-194-10 0 – 60″ ±.004″
552-195-10 0 – 80″ ±.005″

Optional accessories
Interchangeable jaws

Carbon Fiber Caliper

SPECIFICATIONS
Standard Type

Order No. Components a b
07CZA056 Right (07CAA044), Left (07CAA045) 28mm (1.1″) 30mm (1.2″)

* 1 set

Inside Point Type

Order No. Components a b
07CZA058 07CZA041 x 2pcs. 25mm 50mm
07CZA059 07CZA048 x 2pcs. 1″ 2″

Scriber Type

Order No. Components a b
07CZA055 Right (07CZA042), Left (07CZA043) 8mm 30mm
07CZA061 Right (07CZA042), Left (07CZA049) 031″ 1.2″

Surface Plate Type

Order No. a b
07CZA044 90mm (3.5″) 28mm (1.1″)

Centerline Type

Order No. Components a b
07CZA057 07CZA039 x 2pcs. 30mm 30mm
07CZA060 07CZA047 x 2pcs. 1.2″ 1.2″

Note: Entering the appropriate offset value enables the display to indicate the correct measurement value inscribed on the jaws, which should be installed so that this inscription is visible from the display side of the caliper.
Scriber for height gages
Order No. 07GZA000

Type Applicable calipers Range Accuracy whenattached to the caliper

Standard type

552-181-10 (552-191-10) 0 – 450mm ( 0-18”) ±0.06mm ( ±.0025”)
552-182-10 (552-192-10) 0 – 600mm ( 0-24”)
552-183-10 (552-193-10) 0 – 1000mm ( 0-40”) ±0.07mm ( ±.0030”)
552-184-10 (552-194-10) 0 – 1500mm ( 0-60”) ±0.11mm( ±.0045”)
552-185-10 (552-195-10) 0 – 2000mm ( 0-80”) ±0.14mm ( ±.0055”)

Inside point type

552-181-10 (552-191-10) Inside: 50.1-500mm ( 2.004-20”)

±0.09mm( ±.0035”)

Outside: 0 – 450mm ( 0-18”)
552-182-10 (552-192-10) Inside: 50.1-650mm ( 2.004-26”)
Outside: 0 – 600mm( 0-24”)
552-183-10 (552-193-10) Inside: 50.1-1050mm ( 2.004-42”) ±0.10mm ( ±.0040”)
Outside: 0 – 1000mm ( 0-40”)
552-184-10 (552-194-10) Inside: 50.1-1550mm ( 2.004-62”) ±0.14mm ( ±.0055”)
Outside: 0 – 1500mm ( 0-60”)
552-185-10 (552-195-10) Inside: 50.1-2050mm( 2.004-82”) ±0.17mm ( ±.0070”)
Outside: 0 – 2000mm( 0-80”)

Centerline type

552-181-10 (552-191-10) 30.1 – 480mm ( 1.204-19.2”) ±0.08mm ( ±.0030”)
552-182-10 (552-192-10) 30.1 – 630mm ( 1.204-25.2”)
552-183-10 (552-193-10) 30.1 – 1030mmm ( 1.204-41.2”) ±0.09mm ( ±.0035”)
552-184-10 (552-194-10) 30.1 – 1530mm ( 1.204-61.2”) ±0.13mm( ±.0055”)
552-185-10 (552-195-10) 30.1 – 2030mm ( 1.204-81.2”) ±0.16mm ( ±.0065”)

Scriber type

552-181-10 (552-191-10) 30 – 480mm ( 1.2-19.2”) ±0.10mm ( ±.0040”)
552-182-10 (552-192-10) 30 – 630mm ( 1.2-25.2”)
552-183-10 (552-193-10) 30 – 1030mm ( 1.2-41.2”) ±0.11mm ( ±.0045”)
552-184-10 (552-194-10) 30 – 1530mm ( 1.2-61.2”) ±0.15mm ( ±.0060”)
552-185-10 (552-195-10) 30 – 2030mm ( 1.2-81.2”) ±0.18mm ( ±.0070”)
Surface plate 552-181-10 (552-191-10) 0 – 450mm ( 0-17.7”) ±0.10mm( ±.0040”)
552-182-10 (552-192-10) 0 – 600mm ( 0-23.7”)
type
552-183-10 (552-193-10) 0 – 1000mm ( 0-39.4”) ±0.11mm ( ±.0045”)
+
Scriber type for
552-184-10 (552-194-10) 0 – 1500mm ( 0-59.4”) ±0.15mm ( ±.0060”)
height gages
552-185-10 (552-195-10) 0 – 2000mm ( 0-79.6”) ±0.18mm ( ±.0070”)
552-181-10 (552-191-10) Inside: 25.1 – 475mm ( 1.004-19″)
Outside: 0 – 450mm ( 1-18”) ±0.12mm ( ±.0050”)
552-182-10 (552-192-10) Inside: 25.1 – 625mm ( 1.004-25″)
Surface plate Outside: 0 – 600mm ( 1-24”)
552-183-10 (552-193-10) Inside: 25.1 – 1025mm ( 1.004-41″) ±0.13mm ( ±.0055”)
type
+ Outside: 0 – 1000mm ( 1-40”)
Inside point type
552-184-10 (552-194-10) Inside: 25.1 – 1525mm ( 1.004-62″) ±0.17mm ( ±.0070”)
Outside: 0 – 1500mm ( 1-60”)
552-185-10 (552-195-10) Inside: 25.1 – 2025mm ( 1.004-81″) ±0.20mm ( ±.0080”)
Outside: 0 – 2000mm ( 1-80”)
552-181-10 (552-191-10) 15 – 465mm ( 0.6-18.6”) ±0.11mm ( ±.0045”)
Surface plate 552-182-10 (552-192-10) 15 – 615mm ( 0.6-24.6”)
type
552-183-10 (552-193-10) 15 – 1015mm ( 0.6-40.6”) ±0.12mm ( ±.0050”)
+
552-184-10 (552-194-10) 15 – 1515mm ( 0.6-60.6”) ±0.16mm ( ±.0065”)
Centerline type
552-185-10 (552-195-10) 15 – 2015mm ( 0.6-80.6”) ±0.19mm ( ±.0075”)

Application examples

Carbon Fiber Caliper

Technical Data
Accuracy: Refer to the list of specifications. (excluding quantizing error)

Resolution: 0.01mm or .0005″/0.01mm
Display: LCD
Scale type: ABSOLUTE electromagnetic induction linear encoder
Max. response speed: Unlimited
Battery: SR44 (1 pc), 938882, for initial operational checks (standard accessory)
Battery life: Approx. 5,000 hours in continuous use
Dust/Water protection level: IP66 (IEC 60529)* Standard accessory: Jaw clamps (2 pcs.), 05GZA033
* Although these models are IP66 rated, care should be taken to dry tool after use.

Functions
Zero-setting

Data hold
Offsetting
Presetting
Data output
Low-power and low-voltage alert
Counting value composition error
Automatic power on/off, inch/mm reading (inch/mm models)

Standard accessories (2 pcs)

 Carbon Fiber Caliper

Jaw clamps: No.05GZA033 

Optional accessories
For details, refer to page D-39. Connecting cables for IT/DP/MUX
05CZA624: SPC cable with data button (1m)

05CZA625: SPC cable with data button (2m)

Carbon Fiber Caliper

USB Input Tool Direct
06ADV380A: SPC cable for USB-ITN-A (2m)

Connecting  cables  for  U-WAVE-T
02AZD790A: SPC cable for U-WAVE with data button(160mm)

02AZE140A: SPC cable for footswitch

Coolant Proof Carbon Fiber Caliper

SPECIFICATIONS

Metric

Order No. Range* Accuracy
552-150-10 0 – 450mm (20.1 – 470mm) ±0.06mm
552-151-10 0 – 600mm (20.1 – 620mm)
552-152-10 0 – 1000mm (20.1 – 1020mm) ±0.07mm
552-153-10 0 – 1500mm (20.1 – 1520mm) ±0.11mm
552-154-10 0 – 2000mm (20.1 – 2020mm) ±0.14mm

* ( ): Dimension in inside measurement

Inch/Metric

Order No. Range* Accuracy
552-160-10 0 – 18″ (.504 – 18.5″) ±.0025”
552-161-10 0 – 24″ (.504 – 24.5″)
552-162-10 0 – 40″ (1.004 – 40.5″) ±.003”
552-163-10 0 – 60″ (1.004 – 60.5″) ±.0045”
552-164-10 0 – 80″ (1.004 – 80.5″) ±.0055”

* ( ): Dimension in inside measurement

DIMENSIONS

Coolant Proof Carbon Fiber Caliper

Range E F H K L N P U
0 – 450mm (0-18″) 91.8 65.5 25 173 680 89 8 10

(.25″)

0 – 600mm (0-24″) 830
0 – 1000mm (0-40″)

113.8

73

32

170.5

1280

110

12

10

(.5″)

0 – 1500mm (0-60″) 1790
0 – 2000mm (0-80″) 2300

( ): Inch/Metric type

Technical Data
Accuracy: Refer to the list of specifications. (excluding quantizing error)

Resolution: 0.01mm or .0005″/0.01mm
Material of jaws: Stainless Steel Hardened
Display: LCD
Scale type: ABSOLUTE electromagnetic induction linear encoder
Max. response speed: Unlimited
Battery: SR44 (1 pc), 938882,
for initial operational checks (standard accessory)
Battery life: Approx. 5,000 hours in continuous use
Dust/Water protection level: IP66 (IEC 60529)*
Standard accessory: Jaw clamps (2 pcs.), 05GZA033
*This model is not waterproof type. Please wipe away the wet after use.

Functions Zero-setting Data hold Offsetting Presetting Data output
Low-power and low-voltage alert Counting value composition error Automatic power on/off, inch/mm reading (inch/mm models)

Optional accessories
For details, refer to page D-39.

Connecting cables for IT/DP/MUX
05CZA624: SPC cable with data button (1m)

05CZA625: SPC cable with data button (2m)

Coolant Proof Carbon Fiber Caliper

USB Input Tool Direct
06ADV380A: SPC cable for USB-ITN-A (2m)

Connecting  cables  for  U-WAVE-T
02AZD790A: SPC cable for U-WAVE with data button (160mm)

02AZE140A: SPC cable for footswitch

Carbon Fiber Caliper

SPECIFICATIONS

Metric

Order No. Range* Accuracy
552-302-10 0 – 450mm (20.1 – 470mm) ±0.04mm
552-303-10 0 – 600mm (20.1 – 620mm) ±0.04mm
552-304-10 0 – 1000mm (20.1 – 1020mm) ±0.05mm
552-305-10 0 – 1500mm (20.1 – 1520mm) ±0.09mm
552-306-10 0 – 2000mm (20.1 – 2020mm) ±0.12mm

* ( ): Dimension in inside measurement

Inch/Metric

Order No. Range* Accuracy
552-312-10 0 – 18″ (.504 – 18.5″) ±.002″
552-313-10 0 – 24″ (.504 – 24.5″) ±.002″
552-314-10 0 – 40″ (1.004 – 40.5″) ±.002″
552-315-10 0 – 60″ (1.004 – 60.5″) ±.004″
552-316-10 0 – 80″ (1.004 – 80.5″) ±.005″

* ( ): Dimension in inside measurement

DIMENSIONS

Carbon Fiber Caliper

Range D E G H J L N R S t U
0-450mm 100 91.8 35 25 65 640 41.2 R10 18 8 10
(0-18”) (.25”)
0-600mm 100 91.8 35 25 65 790 41.2 R10 18 8 10
(0-24”) (.25”)
0-1000mm 150 113,8 45 32 100 1230 62.8 R10 24 8 10
(0-40”) (.5”)
0-1500mm 150 113.8 45 32 100 1740 62.8 R10 24 8 10
(0-60”) (.5”)
0-2000mm 150 113.8 45 32 100 2250 62.8 R10 24 8 10
(0-80”) (.5”)

Optional accessories

Metric

No. 552-302-10, 552-155-10, 552-303-

10 and 552-156-10.

No. 552-304-10 and 552-305-10
Clamp box (1 pair) No.914053 No.914054
Distance measurement jaw (1 pair) No.914055
Point ID measuring attachment No.914057

Inch/Metric

No. 552-312-10, 552-165-10,

552-313-10 and 552-166-10

No. 552-314-10, 552-315-10,

552-316-10

Clamp box (1 pair) No.914053 No.914054
Distance measurement jaw (1 pair) No.914056
Point ID measuring attachment No.914058

Carbon Fiber Caliper

Technical Data
Accuracy: Refer to the list of specifications. (excluding quantizing error)
Resolution: 0.01mm or .0005″/0.01mm Material of jaws: Stainless Steel Hardened Display: LCD
Scale type: ABSOLUTE electromagnetic induction linear encoder
Max. response speed: Unlimited
Battery: SR44 (1 pc), 938882,
for initial operational checks (standard accessory) Battery life: Approx. 5,000 hours in continuous use Dust/Water protection level: IP66 (IEC60529)* Standard accessory: Jaw clamps (2 pcs.), 05GZA033

* This model is not waterproof type. Please wipe away the wet after use.

Functions
Zero-setting
Data hold
Offsetting
Presetting
Data output
Low-power and low-voltage alert Counting value composition error Automatic power on/off, inch/mm reading (inch/mm models)

Optional accessories
For details, refer to page D-39. Connecting cables for IT/DP/MUX
05CZA624: SPC cable with data button (1m)
05CZA625: SPC cable with data button (2m)

Carbon Fiber Caliper

USB Input Tool Direct
06ADV380A: SPC cable for USB-ITN-A (2m)
Connecting  cables  for  U-WAVE-T
02AZD790A: SPC cable for U-WAVE with data button (160mm)
02AZE140A: SPC cable for footswitch

Digimatic Caliper

SPECIFICATIONS

Metric

Order No. Range* Accuracy Remarks
551-301-10 0 – 200mm (10.1 – 210mm) ±0.03mm IP67
551-331-10 0 – 300mm (10.1 – 310mm) ±0.04mm IP67, with offset/preset function for easy inside measurement
551-204-10 0 – 500mm (20.1 – 520mm) ±0.06mm

551-206-10 0 – 750mm (20.1 – 770mm) ±0.06mm
551-207-10 0 – 1000mm (20.1 – 1020mm) ±0.07mm

* ( ): inside measurement
Note: Series 551 is not equipped with a depth bar.

Inch/Metric

Order No. Range* Accuracy Remarks
551-311-10 0 – 8″ (.404” – 8.4”) ±.0015″ IP67
551-341-10 0 – 12″ (.404” – 12.4”) ±.002″ IP67, with offset/preset function for easy inside measurement
551-224-10 0 – 20″ (.504” – 20.5”) ±.0025″

551-226-10 0 – 30″ (.504” – 30.5”) ±.0025″
551-227-10 0 – 40″ (1.004” – 41”) ±.003″

* ( ): inside measurement
Note: Series 551 is not equipped with a depth bar.

DIMENSIONS

Digimatic Caliper

Range A D J S
0 – 200mm 30 60 43 8
0 – 300mm 40.1 90 68 10
0 – 500mm 56 150 115 15
0 – 750mm 56 150 115 15
0 – 1000mm 56 150 115 20

Jaw thickness:
3mm for 0 – 200mm model
3.8mm for 0 – 300mm model
6mm for 0 – 500mm and 0 – 750mm models
8mm for 0 – 1000mm model

Digimatic Caliper

Technical Data
Accuracy: Refer to the list of specifications.

(excluding quantizing error for digital models) Resolution: 0.01mm or .0005″/0.01mm
Display: LCD
Scale type: ABSOLUTE electromagnetic induction linear encoder
Max. response speed:Unlimited
Battery: SR44 (1 pc), 938882,
for initial operational checks (standard accessory)
Battery life: Approx. 3 years under normal use (1 year: 300mm models) (3.5 years: over 300mm models)
Dust/Water protection level: IP67* (models up to 300mm)
*This model is not waterproof type.
Therefore, rustproofing shall be applied after use.

Optional accessories For details, refer to page D-39.
959143: Data hold unit Connecting cables for IT/DP/MUX
05CZA624: SPC cable with data button (1m)*
05CZA625: SPC cable with data button (2m)*

Digimatic Caliper

959149: SPC cable with data button (1m)
959150: SPC cable with data button (2m)
USB Input Tool Direct
06ADV380A: SPC cable for USB-ITN-A (2m)*
06ADV380C: SPC cable for USB-ITN-C(2m)
Connecting cables for U-WAVE-T
02AZD790A: SPC cable for U-WAVE with data button (160mm)*
02AZE140A: SPC cable for footswitch* 02AZD790C: SPC cable for U-WAVE with data button (160mm)
02AZE140C: SPC cable for footswitch
For IP67 models (up to 300mm)

Nib Style Jaws Caliper

SPECIFICATIONS

Metric

Order No. Range* Accuracy Remarks
550-301-10 0 – 200mm (10.1 – 210mm) ±0.03mm IP67
550-331-10 0 – 300mm (10.1 – 310mm) ±0.04mm IP67, with offset/preset function for easy inside measurement
550-203-10 0 – 450mm (20.1 – 470mm) ±0.05mm
550-205-10 0 – 600mm (20.1 – 620mm) ±0.05mm
550-207-10 0 – 1000mm (20.1 – 1020mm) ±0.07mm

* ( ): Inside measurement
Note: Series 550 is not equipped with a depth bar.

Inch/Metric

Order No. Range* Accuracy Remarks
550-311-10 0 – 8″ (.404” – 8.4”) ±.0015″ IP67
550-341-10 0 – 12″ (.404” – 12.4”)

±.002″

IP67, with offset/preset function for easy inside measurement
550-223-10 0 – 18″ (.504” – 18.5”)
550-225-10 0 – 24″ (.504” – 24.5”)
550-227-10 0 – 40″ (.504” – 40.2”) ±.003″

* ( ): Inside measurement
Note: Series 550 is not equipped with a depth bar.

DIMENSIONS

Nib Style Jaws Caliper

Range D J S R
0 – 200mm 60 40.5 8 5
0 – 300mm 75 50.5 12 5
0 – 450mm 100 65 18 10
0 – 600mm 100 65 18 10
0 – 1000mm 140 95 24 10

Jaw thickness:
3mm for 0 – 200mm model
3.8mm for 0 – 300mm model
6mm for 0 – 450mm and 0 – 600mm models
8mm for 0 – 1000mm model

Nib Style Jaws Caliper

Technical Data
Accuracy: Refer to the list of specifications. (excluding quantizing error for digital models)

Resolution: 0.01mm or .0005″/0.01mm
Display:   LCD
Scale type: ABSOLUTE electromagnetic induction linear encoder
Max. response speed: Unlimited
Battery: SR44 (1 pc), 938882,
for initial operational checks (standard accessory)
Battery life: Approx. 3 years under normal use (1 year: 300mm models)
(3.5 years: over 300mm models) Dust/Water protection level: IP67* (models up to 300mm)
*This model is not waterproof type.
Therefore, rustproofing shall be applied after use.

Optional accessories
For details, refer to page D-39.
959143: Data hold unit
Connecting cables for IT/DP/MUX
05CZA624: SPC cable with data button (1m)*
05CZA625: SPC cable with data button (2m)*

Nib Style Jaws Caliper
959149: SPC cable with data button (1m)
959150: SPC cable with data button (2m)
USB Input Tool Direct
06ADV380A: SPC cable for USB-ITN-A (2m)*
06ADV380C: SPC cable for USB-ITN-C(2m)
Connecting cables for U-WAVE-T
02AZD790A: SPC cable for U-WAVE with data button (160mm)*

02AZE140A: SPC cable for footswitch*
02AZD790C: SPC cable for U-WAVE with data button(160mm)
02AZE140C: SPC cable for footswitch
* For IP67 models (up to 300mm)

Height of digits

 Marcal Digital caliper
 Marcal Digital caliper  Marcal Digital caliper  Marcal Digital caliper  Marcal Digital caliper  
Order no. Measuring range mm Measuring range inches Resolution mm/inch Error limit (mm) Error limit inches Standard Depth Rod
4103076
0 – 150
0 – 6″
0.01 / .0005″
0.03 mm
.001″
Factory standard
round

Functions of Marcal Digital Caliper

Height of digits

 Marcal digital caliper
 Marcal digital caliper  Marcal digital caliper  Marcal digital caliper  Marcal digital caliper
Order no. Measuring range mm Measuring range inches Resolution mm/inch Error limit (mm) Error limit inches Standard Depth Rod
4103078
20 – 170
0.8 – 6.7″
0.01 / .0005″
0.03 mm
.001″
Factory standard
none