Call Us: +91-7972969901
Call Us: +91-7972969901
Specifications:
| Column | Pneumatic |
| Type | Standard/Fanuc (Column transmit data (reading) to Fanuc controller O-i / Power Mate / 16 / 18 Series) |
| Input Channels | 1 |
| Air Cut-Off | Without Air Cut-Off / With Air Cut –Off Available (Air gets ON when Plug is placed in the Job else Air will remain OFF). |
| Resolution | 0.1μm/ 0.5μm/ 1μm/ 5μm |
| Units | mm / Inch |
| Display | 6 digit 7 segments |
| Setup | 10 |
| Measurement Modes | Cur, Max, Min, Diff |
| Modes | ID/OD |
| Indications | Reject, OK, Rework |
| Calibration | Single/Double calibration |
| Scaling | Auto / Manual |
| Communication port | RS-232, Wireless modules-optional |
| RS-232 Port | 1/2 (In case of 2 port customer should specify both port requirement) |
| Data Transmission | Auto/Manual |
| Footswitch | Available |
| Output | 3 open collector outputs provided on DB15 |
| Pressure Sensor | Connector Available for connecting Pressure Sensor. |

Specifications:
| Input Channels | 2 |
| Resolution | 0.1, 0.5, 1, 5 µm |
| Units | mm / Inch |
| Display | 6 digit 7 segment |
| Measurement Modes | Curr , Max , Min , Diff |
| Functions | A, B , A+B, A-B |
| Indications | Reject, OK , Rework |
| Calibration | Single/Double calibration |
| Scaling | Auto / Manual |
| Communication port | RS-232. Wireless modules-optional |
| Footswitch | Available |
| Output | 1 CO relay contact |
| Measuring Ranges | 0.1um -9.9999 to 99.9999 1um -99.999 to 999.999 |
| Bar Ranges | 0.1um-10um 0.5um- 50um 1um – 100um 5um – 500um |

Specifications:
| Input Channels | 1 |
| Resolution | 0.1, 0.5, 1, 5 µm |
| Units | mm / Inch |
| Display | 6 digit 7 segment |
| Measurement Modes | Curr , Max , Min , Diff |
| Functions | A |
| Indications | Reject, OK , Rework |
| Calibration | Single/Double |
| Scaling | Auto / Manual |
| Communication port | RS-232. Wireless modules-optional |
| Footswitch | Available |
| Output | 1 CO relay contact |
| Measuring Ranges | 0.1um -9.9999 to 99.9999 1um -99.999 to 999.999 |
| Bar Ranges | 0.1um-10um 0.5um- 50um 1um – 100um 5um – 500um |



Specifications:
| Input Channels | 2 |
| Resolution | 5µm/ 1µm/ 0.5µm/ 0.1µm |
| Units | mm , inch |
| Measurement Modes | Current, Min, Max, Differential |
| Functions | A, B, A+B, A-B |
| Indications | Reject, Ok, Rework |
| Calibration | Single/Double |
| Display | Tricolour 2 Line 7 Digit seven segment display |
| Communication port | RS-232 |
| Outputs | 6 open collector outputs |
| Footswitch interface | Available |
Specifications:
| Input Channels | 1 |
| Resolution | 5µm/ 1µm/ 0.5µm/ 0.1µm |
| Units | mm , inch |
| Measurement Modes | Current, Min, Max, Differential |
| Functions | A PUSH/PULL |
| Indications | Reject, Ok, Rework |
| Calibration | Single/Double |
| Display | Tricolour 1 Line 7 Digit seven segment display |
| Communication port | RS-232 |
| Outputs | 3 open collector outputs |
| Footswitch interface | Available |