- The thin blade-type jaws fit into very small grooves and make previously difficult outside measurements far easier to obtain.
- The outside measuring faces are carbide tipped.
- Allows step measurement.
- Digital models are IP67 Absolute type. No need to reset the origin after switching on. (Refer to page D-8 for a description of Absolute measurement.)
- Allows integration into statistical process control and measurement systems for models with measurement data output connector. Refer to page A-3.
SPECIFICATIONS
Metric Digital model
Order No. | Range | Accuracy |
---|---|---|
573-634 | 0 – 150mm | ±0.02mm |
573-635* | 0 – 150mm | ±0.02mm |
* without thumb roller
Inch/Metric Digital model
Order No. | Range | Accuracy |
---|---|---|
573-734 | 0 – 6″ | ±.001″ |
Metric
Order No. | Range | Accuracy |
---|---|---|
536-134 | 0 – 150mm | ±0.05mm |
536-135 | 0 – 200mm | ±0.05mm |
536-136 | 0 – 300mm | ±0.08mm |
DIMENSIONS
Range | D | d | e | t |
---|---|---|---|---|
0 – 150mm | 40 | 20 | 0.75 | 3 |
0 – 200mm | 50 | 25 | 0.75 | 3 |
0 – 300mm | 64 | 30 | 1 | 3.8 |
Technical Data
Accuracy: Refer to the list of specifications. (excluding quantizing error for digital models)
Resolution*: 0.01mm or .0005″/0.01mm Graduation**: 0.05mm
Display*: LCD
Scale type*: ABSOLUTE electromagnetic induction linear encoder
Max. response speed*: Unlimited
Battery: SR44 (1 pc), 938882,for initial operational checks (standard accessory)
Battery life*: Approx. 3 years under normal use
Dust/Water protection level*: IP67 (IEC 60529)***
* Digital models ** Analog models *** This model is not waterproof type.
Therefore, rustproofing shall be applied after use.
Optional accessories for Digital Models
For details, refer to page D-39. Connecting cables for IT/DP/
05CZA624: SPC cable with data button (1m)
05CZA625: SPC cable with data button (2m)
USB Input Tool Direct
06ADV380A: SPC cable for USB-ITN-A (2m)
Connecting cables for U-WAVE-T
02AZD790A: SPC cable for U-WAVE with data button (160mm)
02AZE140A: SPC cable for footswitch