Strong Points
- Easy to read force values
- Detailed analysis is possible by connecting PC. It helps easy data managements
- Digital functions are available such as OK/NG judgment
- Suitable for shock tests and breaking tests.
Weak Points
- Battery charging time is necessary
- It is difficult to read force changing without the graphing software.
DS2
- Capacity :2N~ 1000N
- Sampling speed :1000Hz
- Accuracy: ±0.2 %F.S.±1digit
- It is ideal for simple measurements with a hand
- Peak value measurements are easy with the peak hold function.
Easy Operating and Simple Type
DS2 SERIES
The digital force gauge helps low and middle force range measurement between 2N and 1000N.
The remarkable points are easy handling with the simple functions, the lightweight and the compact shape.
DS2 series Model List
Model | Capacity | Display | Thread |
DS2-2N | 2N | 2.000N/2000mN(200.0gf) | M6 |
DS2-5N | 5N | 5.000N/5000mN(500.0gf) | |
DS2-20N | 20N | 20.00N(2.000kgf) | |
DS2-50N | 50N | 50.00N(5.000kgf) | |
DS2-200N | 200N | 200.0N(20kgf) | |
DS2-500N | 500N | 500.0N(50kgf) | |
DS2-1000N | 1000N | 1000N/1.000kN(100.0kgf) |
DS2 series Specifications
Accuracy | ±0.2%F.S.±1digit |
Unit of measurement | N, kgF, lbF |
Display update | 4-digit LCD |
Sampling rate | 1000 data/sec. (Max.) |
Functions | Peak hold (tension and compression)/ Comparator (judgement of acceptance or rejection)/ Reversible display / Dumping (2 Levels) |
Output | RS232C/Analog(+/- 1V F.S.) /Mitutoyo digimatic(※1) |
Operating environment | Temperature : 0 to +40 degree Celsius Humidity : 20 -80%RH |
Battery | 10 hours (Full charge for 10 hours) |
Accessory | Attachments (※2)/AC adaptor/Manual/Inspection certificate (Included attachments depend on the force gauge range) |
ZTS
- Capacity :2N~5000N
- Sampling speed:2000Hz
- Accuracy:±0.2%F.S.±1digit
- Capture peak value with high speed sampling
- Clear display.
- Easy and certain data management with included software.
High Repeatability Standard Model
ZTS SERIES
User-friendly and functional model force gauge. It is approved wide-spread measuring purpose from peak measurement to high repeatability measurement.
Standard Type Model List
Model | Capacity | Display | Thread |
ZTS-2N | 2N(200gf) | 2.000N/2000mN(200.0gf) | M6 |
ZTS-5N | 5N(500gf) | 5.000N/5000mN(500.0gf) | |
ZTS-20N | 20N(2kgf) | 20.00N(2.000kgf) | |
ZTS-50N | 50N(5kgf) | 50.00N(5.000kgf) | |
ZTS-100N | 100N(10kgf) | 100.0N(10kgf) | |
ZTS-200N | 200N(20kgf) | 200.0N(20kgf) | |
ZTS-500N | 500N(50kgf) | 500.0N(50kgf) | |
ZTS-1000N | 1000N(100.0kgf) | 1000N/1.000kN(100.0kgf) |
ZTS series specifications
Accuracy | +/-0.2%F.S.+/-1digit(Excepted sensor separated model) |
Unit of measurement(※1) | N, kgf, lbf (※1) |
Display | 4-digit Organic EL |
Sampling rate | 2000 data / sec at maximum |
Function | Customized display (header and footer), Peak hold (tension and compression), Internal 1000 points data memory, Comparator (judgment of OK or NG), Reversible display, Sign inversion, Zero clear timer, +NG alarm, Off timer (auto power off), Dumping, Time display |
Output | Temperature: 0 to +40 degree Celsius, Humidity: 20 to 80%RH |
Operating environment | USB, RS232C, Mitutoyo digimatic (※2), ±2 VDC analog output (D/A), Comparator 3 steps (-NG/OK/+NG), Overload alarm |
Battery | 8 hours (8 hours full charge) |
Accessory | Attachments(※3), AC adapter, Inspection certificate, Data capturing software ZT-Logger, USB cable, Carrying case. |
- The model less than 5N can be displayed mN,the model more than 1000N can be displayed kN. Japanese domestic model does not indicate kgf and lbf units
- Not always available for Mitutoyo digimatic products.
- 3 Please refer to Page 31 for the detail of included attachments.
- The weights are slightly different by the ranges
ZTS series (High Capacity Model)
- Size:Approx.W83×D44.5×H221mm
- Weight:Approx.1100g
- It is available for 2500N to 5000N
- Same functions and performance as ZTS series standard model.
High Capacity Model List
Model | Capacity | Display | Thread |
ZTS-2500N | 2500N (250kgf) | 2500N/2.500kN (250.0kgf) | M10 |
ZTS-5000N | 5000N (500kgf) | 5000N/5.000kN (500.0kgf) |
ZTS series(Sensor Separate Model)
- Size(the indicator only):Approx.W75×D34×H188mm
- Weight(the indicator only):Approx.490g
- Ideal for installing into facilities or measuring under special circumstance due to an external sensor.
- Users can choose from various types of sensors such as waterproof, allowable wide-range temperature, pen shape. The sensor will fulfill the users required measuring conditions or circumstances.Accuracy adjustments and calibrations are necessary when exchanging a load cell.
- It has same functions and performance as ZTS series general type.
Sensor separate type Model List
(When select load cell DPU series)
Mode | Capacity | Display | Thread |
ZTS-DPU-2N | 2N(200gf) | 2.000N/2000mN(200.0gf) | M6 |
ZTS-DPU-5N | 5N(500gf) | 5.000N/5000mN(500.0gf) | |
ZTS-DPU-10N | 10N(1kgf) | 10.00N(1.000kgf) | |
ZTS-DPU-20N | 20N(2kgf) | 20.00N(2.000kgf) | |
ZTS-DPU-50N | 50N(5kgf) | 50.00N(5.000kgf) | |
ZTS-DPU-100N | 100N(10kgf) | 100.0N(10.00kgf) | |
ZTS-DPU-200N | 200N(20kgf) | 200.0N(20.00kgf) | |
ZTS-DPU-500N | 500N(50kgf) | 500.0N(50.00kgf) |
(When select load cell DPU series[High Capacity Model])
Model | Capacity | Display | Thread |
ZTS-DPU-1000N | 1000N(100kgf) | 1000N/1.000kN(100.0kgf) | M10 |
ZTS-DPU-2000N | 2000N(200kgf) | 2000N/2.000kN(200.0kgf) | |
ZTS-DPU-5000N | 5000N(500kgf) | 5000N/5.000kN(500.0kgf) | |
ZTS-DPU-10kN | 10kN(1000kgf) | 10.00kN(1000kgf) | M18P1.5 Depth22 female screw |
ZTS-DPU-20kN | 20kN(2000kgf) | 20.00kN(2000kgf) |
ZTA
- Capacity: 2N~5000N
- Sampling speed:2000Hz
- Accuracy :±0.2%F.S.±1digit
- Advanced functions are equipped
- Enable to output and input displacement. (a linear scale is required)
- Enable to save data to a USB flash drive.
High-functional Type with Various Functions
ZTA series
High functional high-end model. The remarkable points are inputting and outputting for displacement, connecting a USB flash drive and saving the original graph data.
The Highest Functional Model. ZTS Performances and More Additional Functions.
ZTA series model list
Model | Capacity | Display | Thread |
ZTA-2N | 2N(200gf) | 2.000N/2000mN(200.0gf) | M6 |
ZTA-5N | 5N(500gf) | 5.000N/5000mN(500.0gf) | |
ZTA-20N | 20N(2kgf) | 20.00N(2.000kgf) | |
ZTA-50N | 50N(5kgf) | 50.00N(5.000kgf) | |
ZTA-100N | 100N(10kgf) | 100.0N(10kgf) | |
ZTA-200N | 200N(20kgf) | 200.0N(20kgf) | |
ZTA-500N | 500N(50kgf) | 500.0N(50kgf) | |
ZTA-1000N | 1000N(100.0kgf) | 1000N/1.000kN(100.0kgf) |
- The model less than 5N can be displayed mN,the model more than 1000N can be displayed kN. Japanese domestic model does not indicate kgf and lbf units.
- Not always available for Mitutoyo digimatic products.
- Maximum 100 data/sec capturing series of data with a USB flash drive
- Electricity consumption of battery increase when using USB flash drive or connecting a linear scale.
- A USB flash drive is not included.
- Please refer to Page 31 for the detail of included attachments.
- The weights are slightly different by the ranges
ZTA series specifications
Accuracy | +/-0.2%F.S.+/-1digit |
Unit of measurement(※1) | N, kgf, lbf(※1) |
Display | 4-digit Organic EL |
Sampling rate | 2000 data / sec at maximum |
Function | Customised display (header and footer), Peak hold (tension and compression), Internal 1000 points data memory, Comparator (judgement of OK or NG), Reversible display, Sign inversion, Zero clear timer, +NG alarm, Off timer (auto power off), Dumping, Time display, 1st/2nd peak, Displacement detection at force peak value, Displacement zero reset at selected force |
Output | USB, RS232C, Mitutoyo digimatic (※2), 2 VDC analog output (D/A), Comparator 3 steps (-NG/OK/+NG), Overload alarm, Sub comparator 2 steps (output of large or small judgment), USB flash drive(※3), Displacement(※4) |
Operating environment | Temperature: 0 to +40 degree Celsius, Humidity: 20 to 80%RH |
Battery | 8 hours (8 hours charge) |
Accessory(※5) | Attachments (※6),AC adapter, Inspection certificate, CD driver (including simple software for data logging), (The set of attachments varies according to range.), USB cable, Carrying case, Adaptor for USB flash drive |
ZTA series (High Capacity Model)
- Size :Approx.W83×D44.5×H221 mm
- Weight :Approx.1100g
- It is available for 2500N to 5000N
- Same functions and performance as ZTA series standard model.
High Capacity Model List
Model | Capacity | Display | Thread |
ZTA-2500N | 2500N (250kgf) | 2500N/2.500kN (250.0kgf) | M10 |
ZTA-5000N | 5000N (500kgf) | 5000N/5.000kN (500.0kgf) |
ZTA series (Sensor Separate Model)
- Size(the indicator only):Approx.W75×D34×H188mm
- Weight (the indicator only):Approx.490g
- Ideal for installing into facilities or measuring under special circumstance due to an external sensor.
- ◎Users can choose from various types of sensors such as waterproof, allowable wide-range temperature, pen shape. The sensor will fulfill the users required measuring conditions or circumstances.
- ※Accuracy adjustments and calibrations are necessary when exchanging a load cell.
- It has same functions and performance as ZTA series general type.Check changing value on graphs
 
Sensor separate type Model List (When select load cell DPU series)
Mode | Capacity | Display | Thread |
ZTA-DPU-2N | 2N(200gf) | 2.000N/2000mN(200.0gf) | M6 |
ZTA-DPU-5N | 5N(500gf) | 5.000N/5000mN(500.0gf) | |
ZTA-DPU-10N | 10N(1kgf) | 10.00N(1.000kgf) | |
ZTA-DPU-20N | 20N(2kgf) | 20.00N(2.000kgf) | |
ZTA-DPU-50N | 50N(5kgf) | 50.00N(5.000kgf) | |
ZTA-DPU-100N | 100N(10kgf) | 100.0N(10.00kgf) | |
ZTA-DPU-200N | 200N(20kgf) | 200.0N(20.00kgf) | |
ZTA-DPU-500N | 500N(50kgf) | 500.0N(50.00kgf) |
(When select load cell DPU series[High Capacity Model])
Mode | Capacity | Display | Thread |
ZTA-DPU-1000N | 1000N | 1000N (1.000kN) | M10 |
ZTA-DPU-2000N | 2000N | 2000N (2.000kN) | |
ZTA-DPU-5000N | 5000N | 5000N (5.000kN) | |
ZTA-DPU-10kN | 10kN | 10.00kN | M18P1.5 Depth22 female screw |
ZTA-DPU-20kN | 20kN | 20.00kN |