• ABSOLUTE electromagnetic induction linear encoder system is introduced.
  • Due to the low measuring force, these calipers are ideal for measuring elastic workpieces such as plastic parts and rubber parts that standard calipers cannot measure accurately.
  • Allows fine feeding easily by using thumb roller.
  • Displacement of main scale jaw is 0.3mm.
  • Measuring force: 0.49N to 0.98N (0.5gf to 1.0gf)
  • Absolute type. (Refer to page D-8 for a description of Absolute measurement.)
  • Allows integration into statistical process control and measurement systems for models with measurement data output connector.
    Refer to page A-3.

Low Force Caliper

SPECIFICATIONS

Metric

Order No. Range Accuracy*
573-191-30 0 – 180mm ±0.05mm

* Excluding quantizing error.
Note: Dedicated for outside measurement (depth bar is not fitted).

Inch/Metric

Order No. Range Accuracy*
573-291-20 0 – 7″ ±.002″

DIMENSIONS

Low Force Caliper

Low Force Caliper

Technical Data

Accuracy: Refer to the list of specifications. (excluding quantizing error)
Resolution: 0.01mm or .0005″/0.01mm
Display: LCD
Scale type*: ABSOLUTE electromagnetic inductive linear encoder
Jaw retraction: 0.3mm
Max. response speed: Unlimited
Battery: SR44 (1 pc), 938882,
for initial operational checks (standard accessory)
Battery life: Approx. 3.5 years under normal use.

Optional accessories

For details, refer to page D-39.
959143: Data hold unit
Connecting cables for IT/DP/MUX
959149: SPC cable with data button (1m)
959150: SPC cable with data button (2m)

USB Input Tool Direct
06ADV380C: SPC cable for USB-ITN-C (2m)

Connecting cables for U-WAVE-T
02AZD790C: SPC cable for U-WAVE with data button (160mm)
02AZE140C:
SPC cable for footswitch