SPECIFICATIONS

Metric

  Order No. Range Resolution Accuracy* Anvil dia. Flatness Parallelism Measuring force

 

Digimatic  (LCD)

369-250-30 0 – 25mm

 

 

 

 

0.001mm

±4µm

 

 

020

 

 

 

 

1µm

4µm

 

369-251-30 25 – 50mm
369-252-30 50 – 75mm ±6µm 6µm
369-253-30 75 – 100mm
Quickmike type  (LCD) 369-411 0 – 30mm

 

 

±4µm

4µm
369-412 25 – 55mm
Quickmike type adjustable measuring force (LCD) 227-221 0 – 15mm

 

014.3

 

3µm

0.5N – 2.5N
227-223 0 – 10mm 2N – 10N

* Excluding quantizing error

Metric

  Order No. Range Graduation Accuracy Anvil dia. Flatness Parallelism Measuring force

 

Analog

169-201 0 – 25mm

 

0.01mm

±4µm

 

020

 

1µm

4µm

 

169-202 25 – 50mm
169-205 50 – 75mm ±6µm 6µm
169-207 75 – 100mm
  Order No. Range Graduation Accuracy Anvil dia. Flatness Parallelism Measuring force

 

Digimatic  (LCD)

369-350-30 0 – 1″

 

 

.00005″/

0.001mm

±.0002″

 

 

020

 

 

.00004″

.0002″

 

369-351-30 1″ – 2″
369-352-30 2″ – 3″ ±.0003″ .0003″
369-353-30 3″ – 4″
Quickmike type  (LCD) 369-421 0 – 1.2″ ±.0002″ .0002″
369-422 1″ – 2.2″

* Excluding quantizing error

Inch

  Order No. Range Graduation Accuracy Anvil dia. Flatness Parallelism

 

Analog

169-203 0   – 1″

 

.001″

±.0002″

 

020

 

.00004″

.0002″
169-204 1″ – 2″
169-206 2″ – 3″ ±.0003″ .0003″
169-208 3″ – 4″

DIMENSIONS

Anvil

( ): Adjustable measuring force type

Battery for series 369 and 227

SR44 (1 pc), 938882, for initial operational checks
(standard accessory)
Battery life: Approx. 2.4 years under normal use  (for series 369-2XX, 3XX)
Approx. 1 year under normal use (for series 369-4XX)
Approx. 3 years under normal use (for series 227-2XX)
Length standard: Electromagnetic rotary sensor (for series 369-2XX, 3XX)
Electrostatic capacity absolute sensor (for series 369-4XX, 2XX)
Standard accessories: Reference bar, 1 pc (except for measuring range 0-10mm / 0-15mm / 0-25mm / 0-30mm (0-1″/0-1.2″) models) Spanner (301336), 1 pc (for series 169-2XX, 369-2XX, 3XX) Screwdriver (No.210183), 1pc (for series 227-2XX)

Optional accessories 

Connecting cables
for 369-250-30 to 369-253-30, 369-350-30 to 369-353-30
1m: 05CZA662
2m: 05CZA663

USB Input Tool Direct
USB-ITN-B (2m): 06ADV380B

SPC cables for U-WAVE w/ data switch (160mm): 02AZD790B
For foot switch: 02AZE140B (Refer to page B-68 for details.)

SPC cables for Quickmike and micrometers with adjustable measuring force device
937387: SPC cable (1m)*
965013: SPC cable (2m)*

only for Quickmike and micrometers with adjustable measuring force device

06ADV380E : USB Input Tool Direct with data switch(2m)
02AZD790E : SPC cable for U-WAVE (160mm)
For footswitch: 02AZE140E

Quickmike

Provides a speedy spindle feed of 10mm per thimble rotation, which enables widely differently sized features
to be measured quickly.

Quickmike type with adjustable  measuring force
Digimatic micrometer dedicated to applications requiring
a constant/low measuring force such as measuring wire,
paper, and plastic/rubber parts.